40 - 70
71130/11E/0318
Command AQ
<id>AQ<para5>
Sets measuring range of daily sum of precipitation [mm/d] for the
analogue output.
Access:
Configuration mode (ADMIN).
Description:
This command determines the final value of measuring range of the precipitation daily
sum. With exceeding the final value the automatic summation occurs again from „0“.
The sum is reset at 00:00:00h.
Parameter description:
00AP00010 Sets the measuring range of the precipitation daily sum to 0..10 mm/d.
Value range:
10..100 [mm/d]
Initial value:
100
Command AR
<id>AR<para5>
Scale the analogue wind speed output (Analogue Range).
Access:
Configuration mode (ADMIN).
Description:
Determines the measuring range final value for the analogue wind velocity output. The
standard WEATHER STATION scales the wind speed as follows:
0..10V corresponds to 0..60m/s.
It may however also be advisable to scale the wind speed of 0..30m/s:
0..10V correspond to 0..30m/s.
The end of the measuring range is specified with this parameter. Specification is made
in m/s.
Parameter description:
1..80:
Specifies of the end of the measuring range for wind speed (WS).
If the command AR00045 is input for example, 10V corresponds to a wind speed of
45m/s.
Value range:
1..80[m/s]
Initial value:
60
Command AS
<id>AS<para6>
Test the analogue outputs
(Analogue Static output).
Access:
Configuration mode (ADMIN).
Description:
By means of this command the analogue outputs can be set temporarily, e.g. for a test,
to a required fixed value.
Parameter description:
00AS902500
Sets the analogue outputs to 2500mV.
00AS105000
Sets the analogue WS output to 5000mV.
00AS210000
Sets the analogue WD output to 10000mV.
00AS900000
Sets the analogue outputs to 0mV.
00AS
Resets the analogue outputs to normal mode.
Value range:
0..910000