Cinterion
®
ENS22-E AT Command Set
12.3 AT^SCTM
ENS22-E_ATC_V01.000
19/02/11
Page 164 of 189
Unsolicited Result Codes
URC 1
URCs will be sent to the TE when the temperature reaches or exceeds the critical level, or when it is back to
normal.
^SCTM_B:
URC 2
URC indicated after "
" URC with
value 2 or -2 before the UE switches off.
^SHUTDOWN
Parameter Description
URC presentation mode
0
(P)
Disable URC presentation (except for
equal to -2 or +2).
1
Enable URC presentation.
-2
Below lowest temperature limit (causes immediate switch-off)
-1
Below low temperature alert limit
0
Normal operating temperature
2
Above uppermost temperature limit (causes immediate switch-off)
0
(P)
Suppress output of
in read command.
1
in read command.
Board temperature in Celsius. Is comprised between the lowest temperature warning level and the uppermost
temperature warning level.
Examples
EXAMPLE 1
URCs issued when the operating temperature is out of range:
EXAMPLE 2
URCs issued when the temperature is back to normal (URC is output once):
<UrcMode>
(num)
<UrcCause>
(num)
<tempCtrl>
(num)
<temp>
(num)
^SCTM_B: 2
Alert: Module is above overtemperature limit and switches off.
^SCTM_B: -1
Caution: Module close to undertemperature limit.
^SCTM_B: -2
Alert: Module is below undertemperature limit and switches off.
^SCTM_B: 0
Module back to normal temperature.