U2 COMBINATION VIEWING HEAD AND SIGNAL PROCESSORS
66-2071—02
18
Table 5. Extended Modbus Register Map.
Register
Name
Description
Minimum Maximum Size
40017
SENSORS
Bit mask: shows populated sensors (model dependent,
read only)
UV tube
(0000 0001) 1=on, 0=off
IR sensor
(0000 0010) 1=on, 0=off
SSUV
(0000 0100) 1=on, 0=off
Display
(0000 1000) 1=on, 0=off
Wheel
(0001 0000) 1=on, 0=off
0
255
8 bit
40020
HIGHTEMP
Stores the highest internal temperature (ºC only) the U2
has achieved (read only)
0
261
8 bit
40060
SERIALNUM
Factory set identification number (read only)
-32768
32767
16 bit
40061
IDNUM
User set identification number
-32768
32767
16 bit
40062
OP2HOURS
Total run time in 2 hour increments (read only)
-32768
32767
16 bit
40089
KEYTIMEOUT
Time (in minutes) before the touch wheel will disable itself.
Default of 60. Writing a 0 will disable this function.
0
9999
16 bit
40094
MODEL
Model number of the U2 unit (read only)
-32768
32767
16 bit
40098
HIGHTIME
Time, in 2 hour increments, when the highest temperature
occurred. (read only)
-32768
32767
16 bit
40100
40110
40120
40130
40140
40150
40160
40170
FLAMEON
Flame On setting for file 0
Flame On setting for file 1
Flame On setting for file 2
Flame On setting for file 3
Flame On setting for file 4
Flame On setting for file 5
Flame On setting for file 6
Flame On setting for file 7
51
3425
16 bit
40101
40111
40121
40131
40141
40151
40161
40171
FLAMEOFF
Flame Off setting for file 0
Flame Off setting for file 1
Flame Off setting for file 2
Flame Off setting for file 3
Flame Off setting for file 4
Flame Off setting for file 5
Flame Off setting for file 6
Flame Off setting for file 7
50
3424
16 bit
40102
40112
40122
40132
40142
40152
40162
40172
FFRT
FFRT (flame failure response time) setting for file 0
FFRT (flame failure response time) setting for file 1
FFRT (flame failure response time) setting for file 2
FFRT (flame failure response time) setting for file 3
FFRT (flame failure response time) setting for file 4
FFRT (flame failure response time) setting for file 5
FFRT (flame failure response time) setting for file 6
FFRT (flame failure response time) setting for file 7
1
3
8 bit
40103
40113
40123
40133
40143
40153
40163
40173
TIMEDELAY
Time Delay setting for file 0
Time Delay setting for file 1
Time Delay setting for file 2
Time Delay setting for file 3
Time Delay setting for file 4
Time Delay setting for file 5
Time Delay setting for file 6
Time Delay setting for file 7
0
3
8 bit
40104
40114
40124
40134
40144
40154
40164
40174
UVTGAIN
UV tube gain setting for file 0
UV tube gain setting for file 1
UV tube gain setting for file 2
UV tube gain setting for file 3
UV tube gain setting for file 4
UV tube gain setting for file 5
UV tube gain setting for file 6
UV tube gain setting for file 7
0
7
8 bit