RT (DI2 Configuration) Command
<Serial Interfacing> RT command is used to
dictate the behavior of the DI2/
/CMD line. RT
Command must be issued to enable
flow
control or binary programming.
SB (Stop Bits) Command
SB Command is used to set/read the number of
stop bits in the data packets.
SH (Serial Number High) Command
<Diagnostics> Set/Read the serial number high
word of the module.
SL (Serial Number Low) Command
<Diagnostics> Set/Read the serial number low
word of the module.
AT Command: ATRT
Binary Command: 0x16 (22 decimal)
Parameter Range: 0 – 2
Parameter
Value
Configuration
0 disabled
1
Enable Binary Programming
2 Enable
Flow Control
Default Parameter Value: 0
Number of bytes returned: 1
AT Command: ATSB
Binary Command: 0x36 (54 decimal)
Parameter Range: 0 – 1
Parameter
Value
Configuration
0
1 stop bits
1
2 stop bits
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2B
AT Command: ATSH
Binary Command: 0x25 (37 decimal)
Parameter Range: 0 – 0xFFFF [Read-only]
Number of bytes returned: 2
Related Commands: SL (Serial Number Low)
Minimum Firmware Version Required: 4.27C
AT Command: ATSH
Binary Command: 0x26 (38 decimal)
Parameter Range: 0 – 0xFFFF [Read-only]
Number of bytes returned: 2
Related Commands: SH (Serial Number High)