Kramer Electronics Ltd.
VP-444
– RS-232/Ethernet (UDP) Communication Protocol
52
MIC-TLK
Function
Permission
Transparency
Set:
MIC-TLK
End User
Public
Get:
MIC-TLK?
End User
Public
Description
Syntax
Set:
Set mic talkover parameters
#MIC-TLK
␠
channel,P1,value
␍
Get:
Get mic talkover parameters
#MIC-TLK?
␠
channel,P1
␍
Response
~ nn
@MIC-TLK
␠
channel,P1, value
␍␊
Parameters
P1 (channel)
– 0
P2 (parameter setting)
– 0=Depth, 1=Trigger, 2=Attack time, 3=Hold time, 4=Release time
P3 (value)
– P1 value (in corresponding to P1 units): Depth: 0~100 [%], Trigger: 0~100 (-60dB~40dB),
Attack/Hold/Release time: 0~200 (0~2 sec)
STANDBY
Function
Permission
Transparency
Set:
STANDBY
End User
Public
Get:
STANDBY?
End User
Public
Description
Syntax
Set:
Set Standby mode
#STANDBY
␠
on_off
␍
Get:
Get Standby mode status
#STANDBY?
␍
Response
~ nn
@STANDBY
␠
value
␍␊
Parameters
on_off
– 0=Off; 1=On
MIC-SELECT
Function
Permission
Transparency
Set:
MIC-SELECT
End User
Public
Get:
MIC-SELECT?
End User
Public
Description
Syntax
Set:
Select the microphone
#MIC-SELECT
␠
P1,P2
␍
Get:
Get the microphone
#MIC-SELECT?
␠
P1
␍
Response
Set / Get: ~
nn
@MIC-SELECT
␠
P1,P2,
␍␊
Parameters
P1
– Scaler=1
P2
– Mic mode OFF=[], MIC1=1, MIC2=2, Both=[1,2], [2,1]