2. ETHERNET
44
●
AUDIO - CHANNEL SELECT
LV 58SER40A (DIGITAL AUDIO)
Command Parameter1
Description
8CH
Sets the number of measurement channels to 8ch.
16CH
Sets the number of measurement channels to 16ch.
AUDIO:CH_SEL:NUMBER
?
Queries the number of measurement channels.
1_8CH
Sets the channels that are measured to 1-8ch when the
number of measurement channels is 8ch.
9_16CH
Sets the channels that are measured to 9-16ch when the
number of measurement channels is 8ch.
AUDIO:CH_SEL:DISPLAY
?
Queries the channels that are measured when the number of
measurement channels is 8ch.
●
AUDIO - DISPLAY MODE
LV 58SER40A (DIGITAL AUDIO)
Command Parameter1
Description
LISSAJOU
Displays the Lissajous waveform.
S_IMAGE
Displays the sound image waveform.
STATUS
Displays the audio status screen.
METER
Displays the meter screen.
AUDIO:DISPLAY_MODE
?
Queries the audio display screen.
●
AUDIO - METER SETUP
LV 58SER40A (DIGITAL AUDIO)
Command Parameter1
Description
M60DBFS
Sets the meter scale to 0 to -60dBFS.
M90DBFS
Sets the meter scale to 0 to -90dBFS.
AUDIO:METER:D_RANGE
?
Queries the meter scale.
TRUE_PEAK
Sets the level meter response model to TRUE PEAK.
PPM
Sets the level meter response model to PPM.
PPM1
Sets the level meter response model to PPM1.
PPM2
Sets the level meter response model to PPM2.
VU_TRUE_PEAK
Sets the level meter response model to VU, and peak hold
meter response model to TRUE PEAK.
VU_PPM
Sets the level meter response model to VU, and peak hold
meter response model to PPM.
VU_PPM1
Sets the level meter response model to VU, and peak hold
meter response model to PPM1.
VU_PPM2
Sets the level meter response model to VU, and peak hold
meter response model to PPM2.
LOUDNESS_F
Sets the level meter response model to LOUDNESS-F.
LOUDNESS_S
Sets the level meter response model to LOUDNESS-S.
AUDIO:METER:RESPONSE
?
Queries the meter response model.
0.5SEC
Sets the peak hold time of the peak hold meter to 0.5sec.
1SEC
Sets the peak hold time of the peak hold meter to 1sec.
1.5SEC
Sets the peak hold time of the peak hold meter to 1.5sec.
2SEC
Sets the peak hold time of the peak hold meter to 2sec.
2.5SEC
Sets the peak hold time of the peak hold meter to 2.5sec.
3SEC
Sets the peak hold time of the peak hold meter to 3sec.
3.5SEC
Sets the peak hold time of the peak hold meter to 3.5sec.
4SEC
Sets the peak hold time of the peak hold meter to 4sec.
4.5SEC
Sets the peak hold time of the peak hold meter to 4.5sec.
5SEC
Sets the peak hold time of the peak hold meter to 5sec.
HOLD
Holds the peak time of the peak hold meter.
AUDIO:METER:PEAK_HOLD
?
Queries the holding time of peak hold meter.