Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 11.0 EN · 04/2016 · TD17
109
14
Parameter reference
14.3
Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14885
C14887
C14899
C14900
C14901
Parameter | Name:
C14885 | Clear process data
Data type: UNSIGNED_8
Index: 9690 = 0x25DA
This code is used to set the process data which the I/O device is to process in order to maintain the internal
communication when the fieldbus has exited the "Data_Exchange" status.
Selection list
(Lenze setting printed in bold)
0 Use of most recent master PDOs
1 PDOs are set to the value 0'
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14887 | Suppression diagnostic message
Data type: BITFIELD_8
Index: 9688 = 0x25D8
This code serves to inhibit the transmission of alarm messages to the IO controller. By this, errors of a specific type
can be systematically suppressed. All errors are furthermore entered in the logbook.
Value is bit-coded:
Bit 0 Fault
Bit 1 Fault
Bit 2 Quick stop by trouble
Bit 3 Warning Locked
Bit 4 Warning
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14899 | Station name
Data type: VISIBLE_STRING
Index: 9676 = 0x25CC
The station name must be assigned in accordance with the PROFINET specification. In the standard setting a deleted
name is displayed. The name is also deleted if the "Reset to factory defaults" command is executed by an IO
supervisor or an I/O controller.
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14900 | Firmware product type
Data type: VISIBLE_STRING
Index: 9675 = 0x25CB
The code contains a string with a length of 8 characters. The identification code "E94AFCER" is displayed.
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14901 | Firmware compilation date
Data type: VISIBLE_STRING
Index: 9674 = 0x25CA
The code contains a string with a length of 20 characters. The software creation date ("MMM DD YYYY") and time
("hh:mm:ss") are displayed (e.g. "Mar 21 2005 12:31:21").
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT