3. COMMAND_CLASS_WAKE_UP 
 

Use this command class to specify how often the Power Reader should wake up when in 

normal  mode.  The  command  class  is  implemented  according  to  the  command  class 
specification. 
 
4. COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 
 

The Power Reader is firmware updateable. Performing a firmware update will erase all 

the historical consumption in the Power Reader's memory. The command class is implemented 
according  to  the  command  class  specification.  If  you  want  support  for  firmware  updates  on 
your controlling device contact NorthQ directly for access to latest firmware. 
 
The firmware update request get command must have the following parameters: 

vendor: 

0x96 

product id: 

0x0101 

checksum: 

the checksum is performed on the entire firmware file including headers. Initial crc 

value is 0xFFFF. 
 
5. COMMAND_CLASS_TIME_PARAMETERS 
 

Use this command class to set the Power Reader's real-time clock. The command class is 

implemented according to the command class specification.  

NOTE: 

The Power Reader will not store any timestamped consumption until the real-time clock 

is set. 
 
6. COMMAND_CLASS_METER_V2 
 

Use this command class to get the current total meter consumption. For the electricity 

firmware  the  meter  type  reported  is  0x01  (electricity).  For  gas  firmware  the  meter  type 
reported is 0x02 (gas). 
 

The  scale  for  this  command  class  is  0x00  (kWh  -  for  electricity  meter  and  m

3

  for  gas 

meters). 
 
7. COMMAND_CLASS_CRC_16_ENCAP 
 

This command class is implemented according to the command class specification. Use 

it only if the controlling device is placed in a noisy environment for extra security. 
 
8. COMMAND_CLASS_CONFIG 
 

Through the configuration command class, the controlling node will configure the Power 

Reader. 
 

Summary of Contents for NQ-9021

Page 1: ...NorthQ Power Gas Reader Revision 2 2 1 NorthQ Power and Gas Reader NQ 9021 Technical Integration Z Wave Commands Document revision 2 2 Date January 30 2015...

Page 2: ...ranties or conditions whether expressed orally or implied in law including implied warranties and conditions of merchantability or fitness for a particular purpose NorthQ ApS specifically disclaims an...

Page 3: ...ng has different firmware than the Power Reader for gas metering Please make sure you have the appropriate firmware on your device before you start integrating installing it The proper way of distingu...

Page 4: ...is described in detail Make sure to read the Integrating with third party controllers part of the document after going through the command classes 1 COMMAND_CLASS_BASIC Using the command class basic t...

Page 5: ...entire firmware file including headers Initial crc value is 0xFFFF 5 COMMAND_CLASS_TIME_PARAMETERS Use this command class to set the Power Reader s real time clock The command class is implemented ac...

Page 6: ...ulse factor in imp Wh instead of imp kWh In this case the value must be converted to imp kWh before multiplying by 10 and writing this value in the register In order to convert imp Wh to imp kWh the v...

Page 7: ...e for the Power Reader within 3 seconds then this register should be set to the number of seconds that it will take the controlling node to send a response request to the wake up notification Register...

Page 8: ...irmware Manufacturer 150 Product 1 Product type 1 MANUFACTURER SPECIFIC for gas firmware Manufacturer 150 Product 1 Product type 16 10 COMMAND_CLASS_VERSION This command class is implemented according...

Page 9: ...e wake up node 255 most probably has historical data in his storage You can pull that from the Power Reader as the user might want to see his historical consumption through your UI use the basic comm...

Page 10: ...ess it is absolutely necessary as it will require the antenna to send more bytes than the regular command class By sending more bytes the battery lifetime is affected leave register 10 at 3 seconds If...

Page 11: ...consumption on the meter and the meter disk spins very slow set the pulse count register with the proper value as described in COMMAND_CLASS_CONFIG show the user the real time consumption using comma...

Reviews: