50
・When a measurement is performed once only and no result is
returned, an OK response will be returned after the single
measurement is completed.
Example
To perform a single measurement using all connected F10's, and output
the results to an external signal line:
Input: @XXME̲3̲0[CR]
Output: (No response)
Measurement results will be output to an output signal line only.
・ When results are returned for continuous or synchronous
measurements, a READY response will be returned as soon as the
command is recognized. Results will be output for each measurement
after this response. If a measurement stop command is subsequently
executed, measurements will stop, and an OK response will be
returned after the last measurement result has been output.
Example
To perform synchronous measurement with Unit 3, and return the result
to the serial communications line (where Unit 3 is performing pattern
measurements in Wide Mode, and the comparison result is OK):
Input: @03ME̲2̲1[CR]
Output: @03ME̲READY[CR]
Following this, measurement results will be output to the host each time
the TRIG input signal line turns ON.
Output: 1767[CR]
・
When performing a single measurement and outputting the results,
an OK response will be returned as soon as the command is
recognized. Subsequently, after each measurement is completed,
the result will be output and an OK response will be returned.
Example
To use Unit 27 to measure the image in memory once only, and return
the results by serial communications (with Unit 27 in Plain
Measurement Mode):
49
<comparison̲result><contrast><average̲density>[CR]
:Plain measurement
<comparison̲result><agreement>[CR]
: Pattern measurement at 1 model
<comparison̲result><agreement><agreement>[CR]
: Pattern measurement at 2 models(Wide-mode)
<comparison̲result><agreement><agreement><agreement>[CR]
: Pattern measurement at 3 models(Wide-mode)
<comparison̲result>
0: Comparison result was OK
1: Comparison result was NG
<contrast>
0 to 8:Level of density distribution
<average̲density>
0 to 8:Level of difference between
average density and reference value
<agreement>
0 to 8: Level of density correlation
Agreement is output in the order center, left side, and right side
Explanation
・After executing ME, a measurement stop command must be executed before
proceeding to the next operation. All commands before the measurement stop
will be ignored.
・When the continuous or synchronous measurements do not return results, an
OK response will be returned once the command is recognized. If a
measurement stop command is subsequently executed, an OK response will
be returned at the termination of measurements.
Example
To use Unit 14 in continuous measurement mode and output to an
external signal line only:
Input: @14ME̲1̲0[CR]
Output: @14ME̲OK[CR]
Following this, measurements will be performed while the CONT input
signal line is ON, with measurement results sent to an output signal line.
Example
To stop measurements performed by Unit 14:
Input: @14ME̲0[CR]
Output: @14ME̲OK[CR]