14-Slot AdvancedTCA Shelf
Maintenace
11596-100/-101/-102/-103
www.a-tca.com / www.schroff.biz
22
R1.1, July 23, 2008
4.1.2 Basic CLI Commands
Service personnel can read system information, FRU information and sensor
data with the following basic commands. For a full list of all CLI commands refer
to the Firmware User Manual.
•
Change IP address of the primary Shelf Manager:
clia setlanconfig
channel
ip
value
Value
represents the IP address in dotted decimal notation.
clia setlanconfig 1 ip 192.168.0.2
•
Display the Shelf Managers firmware version:
clia version
Info:
To get a complete list of all information just type in “
version
“.
•
List all IPM Controllers in a Shelf:
clia ipmc
•
List all boards in the Shelf:
clia board
•
List all sensors on a board:
clia sensor
IPMI-address
•
List only sensors which are outside of established thresholds:
clia sensor -t
•
Get data (value) from a sensor on a board:
clia sensordata
IPMI-address sensor-number
•
Display the FRU information in a board:
clia fruinfo
IPMI-address FRU-id
•
Change the speed for a Fan Tray:
clia setfanlevel
IPMI-address Fru-id speed
Info:
The value for the speed is from 0 to 4.
•
Display the contents of the System Event Log (SEL):
clia sel
•
Clear the System Event Log (SEL):
clia sel clear
Summary of Contents for Schroff AdvancedTCA 11596-100
Page 41: ......