36
1072_0_Product_Manual - February 24, 2011 2:52 PM
The minimum data rate that can be set for an analog input, in milliseconds. This is usually 1000.
bool Ratiometric() [get,set]
Sets/returns the state of Ratiometric. Ratiometric = true configures the Analog Inputs to measure w.r.t VCC
(nominal 5V). Ratiometric = false configures the Analog Inputs to measure w.r.t an internal precision 5V
reference. Ratiometric is not updated from the Phidget. It is recommended to explicitly set Ratiometric when
the Interfacekit is opened. After changing the ratiometric state, wait until the ratiometric property matches
what was set before reading analog data.
Events
OnInputChange(int InputIndex, bool State) [event]
An event that is issued when the state of a digital input changes.
OnOutputChange(int OutputIndex, bool State), [event]
An event that is issued when the state of a digital output changes.
OnSensorChange(int SensorIndex, int SensorValue), [event]
An event that is issued when the returned value from a sensor (Analog Input) varies by more than the
SensorChangeTrigger property.