Interface Specification Document
6.3.1.6
Minimum Range Filter (bathy only)
•
DESCRIPTION:
This message sets the minimum value for the range filter.
•
SYNTAX:
*BMIN,N<CR><LF>
•
PARAMETERS:
N – Min range filter [m]. The parameter go from 0 m to max range, but less or equal to
the maximum range filter setting.
•
EXAMPLE:
*BMIN,10<CR><LF>
This example sets the minimum range filter value to 10 m.
6.3.1.7 Contrast
•
DESCRIPTION:
This message sets contrast for the screen.
•
SYNTAX:
*BRIT,N<CR><LF>
•
PARAMETERS:
N – Brightness selection.
0 – 1.0 times.
1 – 1.25 times.
2 – 1.5 times.
3 – 2.0 times.
•
EXAMPLE:
*BRIT,1<CR><LF>
This example sets the contrast to 1.0 times.
6.3.1.8 Calibrate
•
DESCRIPTION:
This message calibrates the system.
•
SYNTAX:
*CALB<CR><LF>
•
PARAMETERS:
None.
•
EXAMPLE:
*CALB<CR><LF>
The system now does a calibration.
______________________________________________________________________
SeaBat 8101 Operator's Manual
6-8
(ISD Rev 1.23) Version 3.02