Response is:
09 10 03 E8 00 03 01 30
where
Bits
Description
09
SlaveID
10
Function Code 16 (Preset Multiple Registers)
03E8
Address of the first register
0003
Number of written registers
0130
Cyclic Redundancy Check (CRC)
Step 5: Read Gripper status until the grip is completed
Request is:
09 03 07 D0 00 03 04 0E
where
Bits
Description
SlaveID
03
Function Code 03 (Read Holding Registers)
07D0
Address of the first requested register
0003
Number of registers requested (3)
040E
Cyclic Redundancy Check (CRC)
Example of response if the grip
:
is not completed
09 03 06 39 00 00 FF 0E 0A F7 8B