Note:

 

use

 

the

 

reset

 

procedure

 

only

 

when

 

the

 

primary

 

controller

 

is

 

missing

 

or

 

inoperable. 

 

Associations 

Through

 

an

 

association

 

this

 

Plug

 

may

 

control

 

another

 

Z

Wave

 

network

 

device,

 

e.g.

 

an 

alarm

 

device,

 

wall

 

plug,

 

lighting

 

etc. 

The

 

Wall

 

Plug

 

provides

 

three

 

association

 

groups,

 

and

 

every

 

group

 

can

 

be

 

supported

 

to 

associated

 

5

 

devices

 

max. 

GROUP

 

1

 

​​

is

 

lifeline

 

service

 

that

 

assigned

 

to

 

plug

 

status

 

 

ON/OFF.

 

It

 

enables

 

the

 

Plug

 

to 

send

 

reports

 

and

 

readings

 

to

 

Z

Wave

 

Controller

 

or

 

Z

Wave

 

Gateway.

 

This

 

Group 

Support:  
NOTIFICATION_REPORT_V4 
METER_REPORT_V4 
SWITCH_BINARY_REPORT 
DEVICE_RESET_LOCALLY_NOTIFICATION 
GROUP

 

2

 

​​

allows

 

for

 

sending

 

control

 

commands

 

to

 

associated

 

devices

 

such

 

as

 

Siren, 

relay

 

module,

 

lighting,

 

etc.

 

If

 

current

 

load

 

is

 

over

 

the

 

max

 

current

 

defined

 

in

 

parameter 

#3,

 

the

 

Plug

 

will

 

send

 

a

 

BASIC_SET

 

(0xFF)

 

to

 

associated

 

devices.

 

When

 

current

 

load

 

is 

normal,

 

plug

 

will

 

send

 

a

 

BASIC_SET

 

(0x00)

 

to

 

associated

 

devices.

 

This

 

Group

 

Support: 

BASIC_SET 
GROUP

 

3

 

​​

allows

 

for

 

Send

 

Notification

 

to

 

associated

 

devices

 

in

 

this

 

group.

 

This

 

Group 

Support: 
NOTIFICATION_REPORT_V4 

Current

 

Load

 

and

 

Energy

 

Consumption 

This

 

Plug

 

provides

 

line

 

voltage,

 

current

 

load,

 

power

 

consumption

 

and

 

energy 

consumption

 

measuring.

 

These

 

measurement

 

results

 

are

 

sent

 

to

 

Z

Wave

 

Controller

 

or 

Z

Wave

 

Gateway. 

Voltage

 

 

​​

The

 

Supply

 

Power

 

Voltage

 

For

 

Plug. 

Current

 

 

​​

The

 

Current

 

for

 

the

 

Electric

 

Device

 

Connect

 

to

 

Plug

 

Consumption. 

Power

 

 

​​

Power

 

Consumed

 

by

 

an

 

Electric

 

Device

 

in

 

an

 

Instant,

 

unit:

 

Watt(W). 

Energy

 

 

​​

Energy

 

Consumed

 

by

 

an

 

Electric

 

Device

 

in

 

a

 

Period.

 

Most

 

commonly 

Measure

 

in

 

Kilowatt

hours

 

(kWh).

 

One

 

kilowatt

hour

 

is

 

Equal

 

to

 

One

 

Kilowatt

 

of

 

Power 

Consumed

 

over

 

a

 

Period

 

of

 

One

 

Hour,

 

1kWh

 

=

 

1000Wh. 

NOTE:

 

​​

Energy

 

(kWh)

 

is

 

default

 

scale

 

for

 

Meter

 

Command

 

Class

 

Version

 

1. 

About

 

Notification

 

CC 

If

 

current

 

load

 

is

 

great

 

than

 

value

 

defined

 

in

 

parameter

 

#3,

 

plug

 

will

 

send 

NOTIFICATION

 

CC

 

to

 

Z

Wave

 

controller.

 

And

 

if

 

there

 

are

 

some

 

devices

 

associated

 

with 

this

 

plug,

 

it

 

will

 

receive

 

a

 

BASIC_SET

 

command

 

from

 

plug. 

Notification

 

Report

 

Command: 

Event

 

Present: 

Command

 

Class:

 

​​

COMMAND_CLASS_NOTIFICATION 

Command:

 

​​

NOTIFICATION_REPORT 

Notification

 

Type:

 

​​

NOTIFICATION_TYPE_POWER_MANAGEMENT 

Event:

 

​​

NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_CURRENT_DETECTED 

Event

 

Clear: 

Command

 

Class:

 

​​

COMMAND_CLASS_NOTIFICATION 

Command:

 

​​

NOTIFICATION_REPORT 

Notification

 

Type:

 

​​

NOTIFICATION_TYPE_POWER_MANAGEMENT 

Event:

 

​​

NOTIFICATION_EVENT_POWER_MANAGEMENT_NO_EVENT 

Over

 

Current

 

Protection

 

Simulating

 

(For

 

Certification

 

Test 

/

 

Production

 

Test) 

When

 

the

 

wall

 

plug

 

is

 

turn

 

on,

 

you

 

can

 

set

 

0xFF

 

to

 

parameter

 

#100

 

through

 

Configure 

Summary of Contents for STW-W3350WU

Page 1: ...nual Power plug Model number STW W3350WU Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference Siterwell Technology HK Co LTD ...

Page 2: ...rnately every 300 milliseconds Please get familiar with the terms below before starting the operations This Plug has function that remembers the relay states the plug will turn on after power up next time if the plug is turn on before the power cut off Manufacture ID 0x0266 Product ID 0x1087 EU Technical Parameters ON OFF control Compatible with 300 series and 500 series Measuring voltage current ...

Page 3: ...controller or gateway operating manual 3 Press the button three times within 1 5 second the device will enter exclusion mode And the LED will flash on and off with yellow alternately five times within 2 seconds Note If device has not been added to Z wave network the device will enter adding mode automatically when it is powered on You should let the controller enter adding mode first before power ...

Page 4: ...rgy consumption measuring These measurement results are sent to Z Wave Controller or Z Wave Gateway Voltage The Supply Power Voltage For Plug Current The Current for the Electric Device Connect to Plug Consumption Power Power Consumed by an Electric Device in an Instant unit Watt W Energy Energy Consumed by an Electric Device in a Period Most commonly Measure in Kilowatt hours kWh One kilowatt hou...

Page 5: ...OWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline Red Led will blink every second until current is normal less than Parameter 3 You must remove the loader and turn on the Plug press the button once to enable current monitor and clear NOTIFICATION ALARM This parameter value must be greater than 4 If user set this parameter to default by Configure CC the parameter 4 will be set to...

Page 6: ...r defines the timer function Enable Disable This parameter can be configured with 0 or 1 where 0 means disable time switch function and 1 enable The period will be defined in parameter 9 If this parameter is Set to 1 and when turn the plug relay on the timer in plug start run with time period defined in parameter 9 and the plug will turn the relay off Function Time switch Configure Parameter Numbe...

Page 7: ...ting This configuration is not influenced to OCP monitor and energy accumulated Function Meter Enable Parameter Number 12 Parameter Size 1 Byte Available Settings 0 1 Default Setting 1 LED Color Indicator LED Color Led Display Status Description Pink Blink 5 Times 1s Interval Power on or Reset and Not Add in Z Wave Network Blink 5 Times 500ms Interval Send Node Info when Press Button tripled Blue ...

Page 8: ...CH_ALL V1 COMMAND_CLASS_BASIC V1 SPECIFICATIONS Power Supply AC110 230V 10 50 60Hz Rate Load Current 13A 110 230V 50 60Hz Continuous Load 16A 110 230V 50 60Hz Momentary Load Power Consumption 0 13W EU Standards Compliance Radio Protocol Z Wave Radio Frequency EU 868 4MHz US 908 4MHz Valid Range Up to 60m outdoors Up to 30m indoors Depending on terrain and building structure Operational Temperature...