Note:
use
the
reset
procedure
only
when
the
primary
controller
is
missing
or
inoperable.
Associations
Through
an
association
this
Plug
may
control
another
Z
‐
Wave
network
device,
e.g.
an
alarm
device,
wall
plug,
lighting
etc.
The
Wall
Plug
provides
three
association
groups,
and
every
group
can
be
supported
to
associated
5
devices
max.
GROUP
1
is
lifeline
service
that
assigned
to
plug
status
–
ON/OFF.
It
enables
the
Plug
to
send
reports
and
readings
to
Z
‐
Wave
Controller
or
Z
‐
Wave
Gateway.
This
Group
Support:
NOTIFICATION_REPORT_V4
METER_REPORT_V4
SWITCH_BINARY_REPORT
DEVICE_RESET_LOCALLY_NOTIFICATION
GROUP
2
allows
for
sending
control
commands
to
associated
devices
such
as
Siren,
relay
module,
lighting,
etc.
If
current
load
is
over
the
max
current
defined
in
parameter
#3,
the
Plug
will
send
a
BASIC_SET
(0xFF)
to
associated
devices.
When
current
load
is
normal,
plug
will
send
a
BASIC_SET
(0x00)
to
associated
devices.
This
Group
Support:
BASIC_SET
GROUP
3
allows
for
Send
Notification
to
associated
devices
in
this
group.
This
Group
Support:
NOTIFICATION_REPORT_V4
Current
Load
and
Energy
Consumption
This
Plug
provides
line
voltage,
current
load,
power
consumption
and
energy
consumption
measuring.
These
measurement
results
are
sent
to
Z
‐
Wave
Controller
or
Z
‐
Wave
Gateway.
Voltage
–
The
Supply
Power
Voltage
For
Plug.
Current
–
The
Current
for
the
Electric
Device
Connect
to
Plug
Consumption.
Power
–
Power
Consumed
by
an
Electric
Device
in
an
Instant,
unit:
Watt(W).
Energy
–
Energy
Consumed
by
an
Electric
Device
in
a
Period.
Most
commonly
Measure
in
Kilowatt
‐
hours
(kWh).
One
kilowatt
‐
hour
is
Equal
to
One
Kilowatt
of
Power
Consumed
over
a
Period
of
One
Hour,
1kWh
=
1000Wh.
NOTE:
Energy
(kWh)
is
default
scale
for
Meter
Command
Class
Version
1.
About
Notification
CC
If
current
load
is
great
than
value
defined
in
parameter
#3,
plug
will
send
NOTIFICATION
CC
to
Z
‐
Wave
controller.
And
if
there
are
some
devices
associated
with
this
plug,
it
will
receive
a
BASIC_SET
command
from
plug.
Notification
Report
Command:
Event
Present:
Command
Class:
COMMAND_CLASS_NOTIFICATION
Command:
NOTIFICATION_REPORT
Notification
Type:
NOTIFICATION_TYPE_POWER_MANAGEMENT
Event:
NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_CURRENT_DETECTED
Event
Clear:
Command
Class:
COMMAND_CLASS_NOTIFICATION
Command:
NOTIFICATION_REPORT
Notification
Type:
NOTIFICATION_TYPE_POWER_MANAGEMENT
Event:
NOTIFICATION_EVENT_POWER_MANAGEMENT_NO_EVENT
Over
Current
Protection
Simulating
(For
Certification
Test
/
Production
Test)
When
the
wall
plug
is
turn
on,
you
can
set
0xFF
to
parameter
#100
through
Configure