118158
‐
001
REV.
A
10
OF
20
1.4.3.5.
Request
High
Voltage
Status
(22)
This
command
requests
that
the
unit
return
current
High
Voltage
(HV)
status
as
follows:
Argument
1
1:
HV
on
0:
HV
off
Example:
Sent
to
Unit
<STX>22,<ETX>
Received
from
unit
<STX>22,0,<ETX>
1.4.3.6.
Request
System
Status
(32)
This
command
requests
that
the
unit
return
the
system
status
as
follows:
1.
Interlock
closed
:
1
Interlock
open
:
0
2.
HV
inhibited
:
1
3.
Over
voltage
fault
:
1
4.
Over
current
:
1
5.
Over
power
:
1
6.
Regulator
error
:
1
7.
Arc
fault
:
1
8.
Over
temperature
:
1
9.
Adjustable
Overload
fault
:
1
10.
System
fault
:
1
11.
Remote
mode
:
1
Local
mode
:
0
Example:
Sent
to
Unit
<STX>32,<ETX>
Received
from
unit
<STX>32,1,1,0,0,0,0,0,0,0,0,1,<ETX>
1.4.3.7.
Clear
Faults
(52)
This
command
clears
faults
remotely.
No
arguments
required.
Example:
Sent
to
Unit
<STX>52,<ETX>
Received
from
unit
<STX>52,$,<ETX>