SBAS492 – JULY 2015
8.5.2.3 Program Register Descriptions
8.5.2.3.1
Auto-Scan Sequencing Control Registers
In AUTO_RST mode, the device automatically scans the preselected channels in ascending order with a new
channel selected for every conversion. Each individual channel can be selectively included in the auto channel
sequencing. For channels not selected for auto sequencing, the analog front-end circuitry can be individually
powered down.
8.5.2.3.1.1
Auto-Scan Sequence Enable Register (address = 01h)
This register selects individual channels for sequencing in AUTO_RST mode. The default value for this register is
FFh, which implies that in default condition all channels are included in the auto-scan sequence. If no channels
are included in the auto sequence (that is, the value for this register is 00h), then channel 0 is selected for
conversion by default.
Figure 109. AUTO_SEQ_EN Register
7
6
5
4
3
2
1
0
CH7_EN
(1)
CH6_EN
CH5_EN
CH4_EN
CH3_EN
CH2_EN
CH1_EN
CH0_EN
R/W-1h
R/W-1h
R/W-1h
R/W-1h
R/W-1h
R/W-1h
R/W-1h
R/W-1h
LEGEND: R/W = Read/Write; -n = value after reset
(1)
Shading indicates bits or registers that are not included in the 4-channel version of the device. A write operation on any of these bits or
registers has no effect on device behavior. A read operation on any of these bits or registers outputs all 1's on the SDO line.
Table 10. AUTO_SEQ_EN Field Descriptions
Bit
Field
Type
Reset
Description
7
CH7_EN
R/W
1h
Channel 7 enable.
0 = Channel 7 is not selected for sequencing in AUTO_RST mode
1 = Channel 7 is selected for sequencing in AUTO_RST mode
6
CH6_EN
R/W
1h
Channel 6 enable.
0 = Channel 6 is not selected for sequencing in AUTO_RST mode
1 = Channel 6 is selected for sequencing in AUTO_RST mode
5
CH5_EN
R/W
1h
Channel 5 enable.
0 = Channel 5 is not selected for sequencing in AUTO_RST mode
1 = Channel 5 is selected for sequencing in AUTO_RST mode
4
CH4_EN
R/W
1h
Channel 4 enable.
0 = Channel 4 is not selected for sequencing in AUTO_RST mode
1 = Channel 4 is selected for sequencing in AUTO_RST mode
3
CH3_EN
R/W
1h
Channel 3 enable.
0 = Channel 3 is not selected for sequencing in AUTO_RST mode
1 = Channel 3 is selected for sequencing in AUTO_RST mode
2
CH2_EN
R/W
1h
Channel 2 enable.
0 = Channel 2 is not selected for sequencing in AUTO_RST mode
1 = Channel 2 is selected for sequencing in AUTO_RST mode
1
CH1_EN
R/W
1h
Channel 1 enable.
0 = Channel 1 is not selected for sequencing in AUTO_RST mode
1 = Channel 1 is selected for sequencing in AUTO_RST mode
0
CH0_EN
R/W
1h
Channel 0 enable.
0 = Channel 0 is not selected for sequencing in AUTO_RST mode
1 = Channel 0 is selected for sequencing in AUTO_RST mode
54