Programming with the Mobile Station 1 & 2

 

 

Mobile Station 1:

 The programming menu in the locomotive menu is only available for certain locomotives. A locomotive with 

a programmable decoder must be selected from the database. Proceed as follows:

 

1. Create a new locomotive and select the item 36330 from the database.The display shows the locomotive Ee 3/3. 
2. Press the "MENU/ESC" button and select the "CHANGE LOCO" section. Here you will find the last function 

 

Programming tab labeled "REG". Use this function to change the CVs of the decoder. You can only write the CVs with this 
function. 

3. Enter the CV number and confirm it with the switch button. 

 

4. Then enter the value of the CV and confirm it with the switch button. The Mobile Station now programs the CV with the 

desired value. 

Mobile Station 2:

 For programming please use the DCC CV programming menu.

 

 

Caution:

 Before programming, remove all locomotives from the track that should not be programmed!

 

 

Table of CVs (Configuration Variables) of the decoder

 

 

IMPORTANT

: All outputs A1 & A2 specified in the table do not apply to

 decoder 73115

 

 

CV

 

Description

 

 

Value range

 

Value ex works

 

1

 

Lokadresse

 

 

 

DCC 1-127

 

3

 

 

 

 

 

Mot 1-80

 

 

2

 

Minimum speed (change until the locomotive moves straight at speed 1)

 

 

1-63

 

1

 

3

 

start-up delay,

 

 

0-255

 

5

 

 

1 means that the current internal speed is increased by 1 every 5 ms

 

 

 

 

 

For example, if the internal maximum speed is 200 (CV 5 = 50 or

 

 

 

 

 

CV 94 = 200), then the start-up time from 0 to Fmax is 1 second

 

 

 

 

4

 

Braking deceleration (time factor

 like CV 3)

 

 

0-255

 

5

 

5

 

Maximum speed

 (must be greater than CV 2)

 

 

1-63

 

48

 

6

 

Average speed

 (must be greater than CV 2 and less than CV 5)

 

 

1-63

 

24

 

7

 

Software version

 (The processor used can be updated)

 

 

-

 

under.

 

8

 

Decoder

 set, values as in CV 59

 

 

various

 

85

 

12

 

Operating modes

 

Wert

 

0-29, 255

 

255

 

 

Bit 0=0

 

DC (analog operation direct current) off

 

0

 

 

 

 

Bit 0=1

 

DC (analog operation direct current) on

 

1*

 

 

 

 

Bit 2=0

 

Data format DCC from

 

0

 

 

 

 

Bit 2=1

 

Data format DCC a

 

4*

 

 

 

 

Bit 3=0

 

Data format Motorola from

 

0

 

 

 

 

Bit 3=1

 

Data format Motorola a

 

8*

 

 

 

 

Bit 4=0

 

Data format Selectrix from

 

0

 

 

 

 

Bit 4=1

 

Data format Selectrix a

 

16*

 

 

 

13

 

Activate function keys in analog mode

 

 

0-255

 

0

 

 

bit 0-7 -> F1 to F8; bit = 0 function off, bit = 1 function on

 

 

 

 

14

 

Activate function keys in analog mode

 

 

0-255

 

1

 

 

bit 0 and bit 4-7 -> F0 and F9 to F12; bit = 0 function off, bit = 1 function on

 

 

 

15

 

Decoder programming lock

 

 

0-255

 

1

 

16

 

Decoder Programming lock Index number

 

 

0-255

 

1

 

17,18

 

Lange Lokadresse

 

 

128-9999

 

2000

 

 

17 = Higher value byte

 

 

192-231

 

199

 

 

18 = Low-valued byte

 

 

0-255

 

208

 

19

 

Consist address

 (double traction)

 

 

1-127

 

0

 

 

0 = Consist address (CADR) is not active

 

 

 

 

 

If bit 7 = 1 the direction of travel is reversed,

 

 

 

 

 

so desired CADR + 128 = reversal of direction

 

 

 

 

27

 

Settings Brake signal (automatic stop)

 

Wert

 

0-179

 

0

 

 

bit 0 = 1 -> ABC right rail positive

 

1

 

 

 

 

bit 1 = 1 -> ABC left rail positive

 

2

 

 

 

 

bit 4 = 1 -> DC with opposite direction of travel

 

16

 

 

 

 

Bit 5 = 1 -> DC with direction of travel equal

 

32

 

 

 

 

Bit 7 = 0 -> ABC only forward direction when bit 0 = 1 or bit 1 = 1

 

0

 

 

 

 

Bit 7 = 1 -> ABC only reverse direction if bit 0 = 1 or bit 1 = 1

 

128

 

 

 

28

 

RailCom

®

 Konfiguration

 

Wert

 

0-131

 

131

 

 

Bit 0 = 1 -> Channel 1 on

 

1

 

 

 

 

Bit 1 = 1 -> Channel 2 on

 

2

 

 

 

 

Bit 7 = 1 -> RailCom Plus®

 a

 

128

 

 

 

29

 

Configuration according to DCC standard

 

Wert

 

0-63

 

14

 

 

Bit 0=0

 

Normal direction of travel

 

0*

 

 

 

 

Bit 0=1

 

Opposite direction of travel

 

1

 

 

 

 

Bit 1=0

 

14 speed steps

 

0

 

 

 

 

Bit 1=1

 

28 speed steps

 

2*

 

 

 

 

Bit 2=0

 

Only digital operation

 

0

 

 

 

 

Bit 2=1

 

Automatic analog/digital switching

 

4*

 

 

 

 

Bit 3=0

 

RailCom®

 switched off

 

0*

 

 

 

 

Bit 3=1

 

RailCom®

 switched on

 

8*

 

 

 

 

Bit 4=0

 

Speed steps via CV 2, 5 and 6

 

0*

 

 

 

 

Bit 4=1

 

Use characteristic curve from CV 67 - 94

 

16

 

 

 

 

Bit 5=0

 

Kurze Adresse (CV 1)

 

0*

 

 

 

 

Bit 5=1

 

Lange Adresse (CV 17/18)

 

32

 

 

 

30

 

Fault memory for function outputs, motor and temperature monitoring

 

0-7

 

0

 

 

1 = Error FKT outputs, 2 = Error motor, 4 = Temperature exceeding

 

 

 

 

Summary of Contents for Intelli Drive 2

Page 1: ...g track 8 Power consumption right red when the programming mode of the control panel is called up When reading or programming very small currents usually flow which do not damage the decoder in the ev...

Page 2: ...de de_DE service download konformit tserkl rung index htm Our advantages for you If you have any questions we are here for you Internet FAQs can be found at www uhlenbrock de E Mail service uhlenbrock...

Page 3: ...tion outputs A1 A2 in the user manual do not apply to the decoder 73115 with 6 pin NEM 651 interface Analog operation with DC voltage The locomotive decoder is suitable for analog operation with DC vo...

Page 4: ...teps via CV 2 CV 5 and CV 6 0 Use characteristic curve from CV 67 94 16 5 Kurze Adresse CV 1 Register 1 0 Long address CV 17 and 18 32 Bit Konfiguration CV 50 Wert 0 Do not use Motorola 2nd address 0...

Page 5: ...1st edition of this description remains valid If braking is initiated with a constant braking distance the decoder only responds to driving commands again when the locomotive has come to a standstill...

Page 6: ...If such an output is switched on via a wireless button it is automatically switched off in the desired direction of travel CV113 2 A1 forward from CV113 4 A2 forward from CV113 8 A3 forward from CV113...

Page 7: ...switch off automatically after an adjustable time without having to switch off the function key Furthermore the decoder can ensure that the coupling is only actuated for a short switch on moment with...

Page 8: ...veral outputs starting and braking delays shunting second dimming of the function outputs SUSI as logic level output transfer of the function keys F22 to F28 to SUSI as well as the setting of the CROS...

Page 9: ...la 256 line 1 16 bytes Formula 256 line 17 16 bytes The bit structure and the values to be programmed accordingly in the CVs are comparable to the configuration CVs of the decoder This means that ther...

Page 10: ...CV 272 1 To facilitate programming especially for extended function mapping the programming software Lok Tool can be used which is included with the digital programming and test station DigiTest from...

Page 11: ...From decoder software version 23 CV7 3rd edition 25 02 19...

Page 12: ...ecoders Programming with a M rklin control unit eg 6021 With a M rklin control panel all CVs can be programmed but not read out The decoder can be put into programming mode in two ways a and b dependi...

Page 13: ...255 255 Bit 0 0 DC analog operation direct current off 0 Bit 0 1 DC analog operation direct current on 1 Bit 2 0 Data format DCC from 0 Bit 2 1 Data format DCC a 4 Bit 3 0 Data format Motorola from 0...

Page 14: ...ht A1 and A2 156Hz 0 Bit 3 1 Frequency light A1 and A2 24KHz 8 Bit 4 0 SUSI SUSI 0 Bit 4 1 SUSI A3 A4 output function mapping table 16 51 Decoder Konfiguration 2 Wert 0 135 3 131 Bit 0 0 Motor control...

Page 15: ...value 200ms 16 240 131 Dynamic smoke generator control load threshold 0 255 5 132 Dynamic smoke generator control PWM normal operation 0 63 16 133 Dynamic smoke generator control PWM idle stand 0 63...

Page 16: ...164 Servo control Servo 2 position 2 function key on 0 255 200...

Page 17: ...es Switching on effect of light and function outputs A1 A2 0 7 0 bit 0 2 A0 to A2 Bit 0 effect off bit 1 effect on 189 Neon tubes turn on effect flash time value 5ms 0 255 20 190 Neon tubes turn on ef...

Page 18: ...16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each until 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 320 3 8 16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 3...