5.2.
Switching A/B Channels
The ASCII switching command uses the following format:
^Abb mm p
[Enter]
Where:
bb
is the Bank Number (00 - 14).
mm
is the Switch Module Number (00 - 14).
p
is the desired switch position (A or B).
Note:
·
There is no space between the “
^A
” character and
the Bank Number.
·
There is one space between the Bank Number and
the Switch Module Number. Likewise, there is one
space between the Switch Module Number and the
desired switch position.
·
The Bank Number and Switch Module Number are
always entered as a two digit number. For example,
Bank Number “3" is entered as ”
03
“, and Switch
Module Number ”6" is entered as “
06
”.
·
If a double zero (
00
) is entered as the Bank Number,
the command will be applied to
all
banks.
·
If a double zero (
00
) is entered as the Switch
Module Number, the command will be applied to all
Switch Modules in the specified bank.
Examples:
·
To toggle Switch Module 11 in Bank Number 1 to the “B”
position, type
^A01 11 B
[Enter]
.
·
To toggle all Switch Modules in Bank number 2 to the “A”
position, type
^A02 00 A
[Enter]
.
·
To toggle Switch Module Number 5 in all banks to the “A”
position, type
^A00 05 A
[Enter]
.
·
To toggle all Switch Modules in all banks to the “B” position,
type
^A00 00 B
[Enter]
.
5-2
RAB-14A User’s Guide