Model 2500A225C
36
Rev A
2.11.13
Machine State Query
This command queries the RF gain, detector gain, ALC threshold, and ALC response time.
Query:
MSB?
Response Format:
RF<space>GAIN=<rf_gain>,DT<space>GAIN=<det_gain>,THRES=<alc_th
resh>,RESP=<resp><LF>
<rf_gain>:
The RF Gain setting (0-100%), padded with leading spaces to be 3 characters
<det_gain>:
The ALC Detector Gain (0-100%), padded with leading spaces to be 3
characters
<alc_thresh>:
The ALC Threshold setting (0-100%), padded with leading spaces to be 3
characters
<resp>:
1 character representing the ALC Response setting (1-7)
Example:
To query the machine state, send the following command:
MSB?<LF>
Response:
RF<space>GAIN=100,DT<space>GAIN=<space>50,THRES=75,RESP=1
<LF>
(RF gain is 100%, Detector Gain is 50%, ALC Threshold is 75%, and ALC
Response Time is set to 5mS)
2.11.14
Amplifier State Query
This command queries the state of the amplifier.
Query:
STATE?
Response Format:
STATE=<space><char1><char2><char3><char4><LF>
<char1> - <char4>:
ASCII character (0 to 9 or A to F) representing a hexadecimal character
Example:
To query the state of the amplifier, send the following command:
STATE?<LF>
Response:
STATE=<space>8301<LF>
(Remote Mode, Power On, RF OFF, and Manual Mode)
Summary of Contents for 0053007
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 2500A225C iv ...
Page 28: ......
Page 70: ...Model 2500A225C 46 Rev A ...
Page 80: ...Model 2500A225C 56 Rev A Figure 4 7 SMA Module Input Figure 4 8 Final Module RF Output ...
Page 82: ...Model 2500A225C 58 Rev A ...
Page 84: ...Model 2500A225C 60 Rev A ...
Page 86: ......