Model 350S1G6A
Rev C
25
2.6.6.14
Operating Hours (RF On)
Query to get the RF On operating hours.
Syntax:
OH?
Parameters:
None
Response Format:
OH=x<LF>
Where:
x
=
0
to
100000
Units are Hours. Values can be up to six digits in length. Leading zeros are read as
spaces.
Example:
To find out the RF On operating hours, send the following query.
OH?<LF>
Response:
OH=<space><space><space><space>37<LF>
(The system has spent 37 Hours in an RF On state)
2.6.6.15
Operating Hours (Power On)
Query to get the Power On operating hours.
Syntax:
OHP?
Parameters:
None
Response Format:
OHP=x<LF>
Where:
x
=
0
to
100000
Units are Hours. Values can be up to six digits in length. Leading zeros are read as
spaces.
Example:
To find out the Power On operating hours, send the following query.
OHP?<LF>
Response:
OHP=<space><space><space>428<LF>
(The system has spent 428 Hours in a Power On state)