BIS V-6108 PROFINET
Processor Unit
34
english
Status codes
Status code
Description of Function
00
hex
Everything OK.
01
hex
Job cannot be run because there is no data carrier in range of the read/write
head.
02
hex
Cannot read the data carrier.
03
hex
Data carrier was removed from the R/W head's range during reading.
04
hex
Cannot write to the data carrier.
05
hex
Data carrier was removed from the R/W head's range during writing.
07
hex
No or invalid command identifier for set AV bit or the number of bytes is 00
hex
.
09
hex
R/W head cable break or no R/W head connected.
0D
hex
Communication to the R/W head disrupted.
0E
hex
CRC for the read data and CRC for the data carrier do not agree.
0F
hex
1st and 2nd bit header are not the same. The 2nd bit header must be used.
20
hex
Address assignment of the read/write job is outside the memory range of the
data carrier.
21
hex
This function is not possible for this data carrier.
30
hex
License key incorrect.
31
hex
Invalid parameter set.
32
hex
Password required.
33
hex
Password invalid.
34
hex
Memory area is locked.
35
hex
Value range of the parameter incorrect.
Description of the Code Present (CP) and Multiple Tag (MT) bits
CP MT Meaning
0
0
No tag in the field
1
0
Exactly one tag in the field. Automatic reading is OK (if configured).
0
1
More than one data carrier is in the field. They cannot be processed.
1
1
Does not occur.
Command Identifier 00
hex
: No Command Present
Subaddress
Meaning
Description of Function
00
hex
1st Bit Header
01
hex
Command Identifier 00
hex
: No command present.
Last byte
2nd Bit Header
Input buffer
Structure of the
commands for
read/write heads
7
Device Functions