118
MANUAL DO USUÁRIO DC-2000 / PROGRAMA WINTASKGEN - Revisão 1.5
Line No.
Operator
Source Operand
Destination
Operand
1
DLY
1000
4.3.12 END
Syntax:
Operator
Source Operand
Destination Operand
END
Description:
End of macro command execution. A process may have several END macros.
Operand Data Type: NONE
Examples:
TEMPVAR is defined as a numeric variable; TEMPVAR will be divided by 100 if it
is greater than 1000, but will be divided by 10, if not.
Line No.
Operator
Source Operand
Destination
Operand
1
CMP
TEMPVAR
1000
2
JMP
GT
5
3
DIV
10
TEMPVAR
4
END
5
DIV
100
TEMPVAR
6
END
4.3.13 EXT
Syntax:
Operator
Source Operand
Destination Operand
EXT
Description:
Exit data collection and go to RUN TASK state.
Operand Data Type: NONE.
4.3.14 GET
Sintaxe:
Operator
Source Operand
Destination Operand
GET
OPERAND1
OPERAND2