18-32
August 2003
Access Navigator - Release 1.8
CLI Language Reference
CLI Command List
assigned to another remote interface, you must use the
disconnect
interface
command before making new connections (see
Disconnect Remote
on
page 18-34
).
You can use the
show
remote
connect
command to display the current settings in
the Access Navigator data base (see
Show Remote
on
page 18-150
). After downloading
the configuration to the Access Bank II, you can verify those connections by using the
read
remote
connect
command to read and display the settings from the remote
Access Bank II (see
Read Remote Connections
on
page 18-48
).
Security:
Level 2 (operator)
Syntax:
connect remote
<"
name
">
<
fx
|
rs232
|
sdsl
|
t1drop
|
v35
>
Example:
connect remote "AcmeT1" t1drop
Example:
connect remote "AcmeV35" v35
Delete Interface
Purpose:
Removes a fractional interface created by the
add
interface
command. It will also
disconnect DS0s attached to the interface.
Security:
Level 2 (operator)
Syntax:
delete interface
<"
name
">
Example:
delete interface "AcmeV35"
Field
Description
name
The user defined name for the fractional interface, as created by
the
add
interface
command. The name must be enclosed in
quotes.
fx
Connect fractional interface from remote FX port to T1 Drop
port.
rs232
Connect fractional interface to remote RS-232 interface port.
sdsl
Connect fractional interface to remote SDSL interface port.
t1drop
Connect fractional interface to remote T1 Drop interface port.
v35
Connect fractional interface to remote V.35 interface port.
Field
Description
name
The user defined name for the interface. The name must be
enclosed in quotes.
Summary of Contents for Access Navigator
Page 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Page 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Page 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Page 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Page 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Page 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...
Page 668: ...C 10 August 2003 Access Navigator Release 1 8 SNMP Interface SNMP Trap Reports ...
Page 682: ...GlossaryGlossaryGlossaryGlossary 14 August 2003 Access Navigator Release 1 8 Glossary ...
Page 704: ...Index 1 22 August 2003 Access Navigator Release 1 8 Index ...