Note: The C command can be used to set prefixes and suffixes. Please refer to section 7.4 for more
information.
Note: The C command saves changes immediately and those settings will survive a reboot. It is
equivalent to issuing a P and =, then a W command. C(2B)0 is the same as these three commands
combined: P(2B)0, =(2B)0, W
(The Reader will respond with d or e.)
Note: Also see commands O, P, Q, /, =, W. See Section 9 for possible Reader settings.
G
Get setting from Reader if followed by a register number in parenthesis.
G([prefix|suffix]) will return the prefix or suffix text.
(The Reader will respond with d and the setting value or with e. The setting value, if numeric, will be
in hexadecimal, padded to 8 digits.)
Note: see Section 9 for possible Reader settings.
H
Requires subcommand. See below.
$ – Lock
$
Commands to lock and unlock the reader with a PIN.
Lock and Unlock the reader using the CR5000AV Configurator section of the Web
Configuration Guide.
By default, commands can be sent to the reader from a host (such as CortexTools or
CortexMobile) even if the reader is locked. Commands can also be sent to a locked reader by
embedding them in a Keyed Configuration Code. These Keyed Configuration Codes are
generated by the Web Configuration Guide for CR5000AV commands, and will soon be
generated by CortexTools and CortexMoble for general commands.
Sub-Commands:
Command
Description
R Reset PIN
and Unlock
Reader
If this command is sent to the reader via barcode the read must be
triggered by a physical button press. The reader can not be in
Continuous Scan or Motion Detection modes to read the barcode.
The reader must be rebooted within 30 seconds of receiving this
command in order to actually reset the reader. If the reader is not
rebooted within 30 seconds, the reader will error beep and return to
its previous, locked state.
Example: H$R
Keyword: #Lock