Configures in on-counter (In-Stand) or off-counter (Out-of-Stand) behavior of the CR5000 &
CR5000RTC to the specified mode. These codes are designed to configure complex modes in
a single command, even if Code adds or changes some of the underlying commands at a later
date.
Format: H5(in|out)<mode>
in|out
o
in – configures the reader’s on-counter (In-Stand) behavior
o
out – configures the reader’s off-counter (Out-Of-Stand) behavior
mode
# Mode
Description
0 Trigger
Scan on trigger press, use targeting LEDs otherwise. Does not block
duplicate barcodes.
1 Pick List
Scan on trigger press, use targeting LEDs otherwise. The barcode must
be near the center of the reader’s field of view to be decoded. Does not
block duplicate barcodes.
2 Detect
Barcode
Continuous scanning with IR illumination. If a barcode is detected,
switch to red illumination. Will not output the barcode a second time
while it remains in the field of view.
3 Detect
Motion
Continuous scanning with IR illumination. If motion is detected, switch
to red illumination. Will not output the barcode a second time while it
remains in the field of view.
4 Always On
Continuous scanning with dim red illumination. If a barcode is detected,
switch to normal red illumination. Will not output the barcode a second
time while it remains in the field of view.
For example, to configure the reader for Trigger mode when handheld, use the H5(out)1
command. To configure the reader for Always On mode when on the counter, use the
H5(in)4 command.
Keywords: #Stand
A – Encryption Commands