45
7. IR Commands
COMMAND
DESCRIPTION AND PARAMETERS
SET IR N1 LEARN N2
Initiate the IR learning function on IR Input
N1. The captured IR code will be written to
command slot N2.
Available values for N1:
1
[IR input on Tx]
2
[IR input on Rx]
N2 = 1 ~ 128
[Command number]
Notes: The capture function will timeout
automatically after 15 seconds if no signal is
received. The command index must already
have a valid name assigned to it to store IR
data.
SET IR N1 EMIT N2
Emit the IR code stored in command N2
over IR Output N1.
Available values for N1:
A
[IR output on Tx]
B
[IR output on Rx]
N2 = 1 ~ 128
[Command number]