5.1.3 1-** Load and Motor
Param
eter
numb
er
Parameter description
Default value
2 set-up
Change during
operation
Conversion
index
Type
1-0* General Settings
1-00
Configuration Mode
[0] Open Loop
All set-ups
TRUE
-
Uint8
1-01
Motor Control Principle
[1] VVC+
All set-ups
FALSE
-
Uint8
1-06
Clockwise Direction
[0] Normal
1 set-up
FALSE
-
Uint8
1-1* Motor Selection
1-13
Compressor Selection
ExpressionLimit
2 set-ups
TRUE
-
Uint8
1-2* Motor Data
1-20
Motor Power
ExpressionLimit
All set-ups
FALSE
-
Uint8
1-22
Motor Voltage
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-23
Motor Frequency
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-24
Motor Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
1-25
Motor Nominal Speed
ExpressionLimit
All set-ups
FALSE
67
Uint16
1-26
Motor Cont. Rated Torque
ExpressionLimit
All set-ups
FALSE
-1
Uint32
1-29
Automatic Motor Adaption (AMA)
[0] Off
All set-ups
FALSE
-
Uint8
1-4* Adv. Motor Data II
1-42
Motor Cable Length
10 m
All set-ups
FALSE
0
Uint8
1-43
Motor Cable Length Feet
33 ft
All set-ups
FALSE
0
Uint16
1-44
d-axis Inductance Sat. (LdSat)
ExpressionLimit
All set-ups
FALSE
-6
Int32
1-45
q-axis Inductance Sat. (LqSat)
ExpressionLimit
All set-ups
FALSE
-6
Int32
1-48
Current at Min Inductance for d-axis
70 %
All set-ups
FALSE
0
Int16
1-49
Current at Min Inductance for q-axis
70 %
All set-ups
FALSE
0
Uint16
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
100 %
All set-ups
TRUE
0
Uint16
1-52
Min Speed Normal Magnetising [Hz]
0 Hz
All set-ups
TRUE
-1
Uint16
1-55
U/f Characteristic - U
ExpressionLimit
All set-ups
FALSE
-1
Uint16
1-56
U/f Characteristic - F
ExpressionLimit
All set-ups
FALSE
-1
Uint16
1-6* Load Depen. Setting
1-66
Min. Current at Low Speed
50 %
All set-ups
TRUE
0
Uint32
1-7* Start Adjustments
1-70
Start Mode
[1] Parking
All set-ups
TRUE
-
Uint8
1-71
Start Delay
60 s
All set-ups
TRUE
-1
Uint8
1-72
Start Function
[2] Coast/delay time
All set-ups
TRUE
-
Uint8
1-73
Flying Start
[1] Enabled Always
All set-ups
TRUE
-
Uint8
1-75
Start Speed [Hz]
100 Hz
All set-ups
TRUE
-1
Uint16
1-78
Compressor Start Min. Speed [Hz]
29 Hz
All set-ups
TRUE
-1
Uint16
1-79
Compressor Start Max Time to Trip
3 s
All set-ups
TRUE
-1
Uint8
1-8* Stop Adjustments
1-80
Function at Stop
[0] Coast
All set-ups
TRUE
-
Uint8
1-82
Min Speed for Function at Stop [Hz]
0 Hz
All set-ups
TRUE
-1
Uint16
1-87
Compressor Min. Speed for Trip [Hz]
28 Hz
All set-ups
TRUE
-1
Uint16
1-9* Motor Temperature
1-90
Motor Thermal Protection
[4] ETR trip 1
All set-ups
TRUE
-
Uint8
1-93
Thermistor Source
[0] None
All set-ups
FALSE
-
Uint8
Table 5.2
Parameter Lists
Programming Guide
MG18P202