A
Technical appendix
Festo – SBRD-EN – 2017-11 – English
65
Name
Comments
Value
Type
FW
Read/
Write
Error status
R
23
Uint16
Detected parts type bit 0
R
24
Uint16
Independent of the job parameter
output module format.
Detected parts type is binary coded
(bit 0 to bit 7):
00000000 = parts type 1
00000001 = parts type 2
…
11111111 = parts type 256
Detected parts type bit 1
R
25
Uint16
Detected parts type bit 2
R
26
Uint16
Detected parts type bit 3
R
27
Uint16
Detected parts type bit 4
R
28
Uint16
Detected parts type bit 5
R
29
Uint16
Detected parts type bit 6
R
30
Uint16
Detected parts type bit 7
R
31
Uint16
Tab. A.6
Output register
A.3.3
Quick access to input and output register
Name
Read/
Write
FW
Value
Type
Allowed
Values
Comments
Quick access to
detected parts type
R
32
Uint16
Corresponds to flag word 24 to 31
Quick access to job
preselection
R/W
33
Uint16
1 to 255
during
writing
Corresponds to flag word 8 to 15.
For takeover, the input takeover
signal must then be set. During
reading, the currently used job
number is returned.
Tab. A.7
Quick access to input and output register
A.3.4
Extended system status/system information
Name
Read/
Write
FW
Value
Type
Comments
Error code of
the current error
R
100
Uint16
0 = No error
X = Error number (table in Chapter A.2)
Error code of
the current warning
R
101
Uint16
0 = No error
X = Error number (table in Chapter A.2)
Device type
R
102
Uint16
SBRD: 714
Version of the major
firmware
R
103
Uint16
For example, Version 3.2.0.9:
high byte = 3, low byte = 2
Version of the minor
firmware
R
104
Uint16
For example, Version 3.2.0.9:
high byte = 0, low byte = 9