A
Technical appendix
68
Festo – SBRD-EN – 2017-11 – English
Name
Comments
Value
Type
FW
Read/
Write
Number of all
characteristics used
R
266
Uint16
Number of all characteristics that were
previously configured in the CCS software
in the selected job for testing of objects
è
Job Navigator, step 4, Prepare test or Job
Navigator, step 5, Test objects.
Number of
characteristics that are
defined in the result
flag word
R
267
Uint16
Only those characteristics are considered that
were previously configured in the CCS
software in the selected job for output of
result flag words
è
Job Navigator, step 6,
Configure I/O, selection result flag words.
Summary of
the characteristic
results
R
300 –
315
Uint16
Results of up to 256 characteristics are
summarised at bit level for every 16 bits
(= 1 flag word).
Characteristic result:
0 = Not OK, 1 = OK
Only those characteristic results are
considered that were previously configured
in the CCS software in the selected job for
output of result
flag words
è
Job Navigator,
step 6, Configure I/O, selection result flag
words.
Tab. A.11 Basic results of the last test
A.3.8
Freely usable flag words (not remanent)
Name
Read/
Write
FW
Value
Type
Comments
Free flag words (not
remanent)
R/W
320 –
383
Uint16
Flag words are 16 bit memory locations to which
no function is assigned as standard. Flag words
are filed in the main memory of the camera
system, but not permanently stored. The data
in these flag words are lost when the power
supply is switched off.
Tab. A.12 Freely used flag words (not remanent)
A.3.9
Configure cameras
Addressing of the cameras is summarised in sections. The sections begin with flag word 1000 and are
each offset by 500.
–
Section of the 1st camera begins with 1000.
–
Section of the 2nd camera begins with 1500.