54
•
BadType
: Module in slot is not expected type.
•
Extra
: Module in slot but no module expected in this position.
•
--
: No module fitted and no module expected in this slot.
Examples of Slot Use
Intentionally Empty Slot
If a slot is intentionally left empty:
• The
Unit Type
field will show
No Unit Fitted
, and the
Unit ID
field will show
No Unit
.
• The
User-Defined Name
field will be empty and the
Bound Unit ID
window will display
None
.
In the absence of other modules, the Gateway will not log
Module Status
for this slot position.
Correct Module Fitted
If a module is fitted that matches the
Bound Unit ID
, the
User-Defined Name
will be used in
the network browser.
In the absence of other modules, the Gateway will log
Module Status
as
OK
, and display
Module Status = OK
on the
Logging
). The Gateway also logs
MSG=UNIT
PRESENT
for the slot position.
Module Absent - Unit Bound
If a slot is intended to have a particular module fitted (as set by the
Bound Unit ID
function),
but no module is fitted, the
Unit Type
field will display
No Unit Fitted
and the
Unit ID
field will
display
No Unit
. However, the
User-Defined Name
field will show the intended name and the
Bound Unit ID
field will display the intended ID.
In the absence of other modules, the Gateway will log
Module Status
as
1 Module Missing
,
and show
Module Status = 1 Module Missing
on the
Logging
page (see
). The
Gateway also logs
MSG=UNIT LOST
for the slot position.
Module Fitted - No Unit Bound
If a module is fitted in a slot but no
Bound Unit ID
is assigned to the slot, the generic type
name for the module type will be displayed, and the slot will appear in the network browser by
its slot number and generic type.
In the absence of other modules, the Gateway will log
Module Status
as
1 Extra Module
, and
show
Module Status = 1 Extra Module
on the
Logging
page (see
). The Gateway also
logs
MSG=UNIT PRESENT
for the slot position.
Incorrect Module Fitted
If a module is fitted that does not match the
Bound Unit ID
, the
User-Defined Name
will not
be used and the generic type and slot number will appear in the network browser.
In the absence of other modules, the Gateway will log
Module Status
as
1 Extra Module
, and
show
Module Status = 1 Extra Module
on the
Logging
page (see
). The Gateway also
logs
MSG=UNIT PRESENT
for the slot position.
Non-RollCall Module Fitted
If a card that is passive to RollCall is fitted in a slot, select the
Non-RollCall Enable
check box.
The Gateway will simulate a RollCall compatible card in the relevant slot, and raise awareness
to RollLog and RollMap. In the
IDNAME
field, enter a name for the unit so that it can be
recognized.
For the module, the Gateway will log
MSG=NON ROLLCALLMODULE
, and
IDNAME=<user defined>
.
Summary of Contents for IQH4B