31
—
AP-
16
00T-
PMCL
Calculate the H_Period using the following formulas when cutting out a portion of the
image using ROI.
H_Count = Max(Sensor_H_Max, CL_H_Count_Max)
H_Period = H_Count / 74.25MHz
The Sensor_H_Max values and Pack Value are as follows for each ClConfiguration,
PixelFormat and CameraLink Clock Frequency.
Base/RGB8
612
612
612
Medium/RGB8
612
612
612
Medium/RGB10
612
612
612
Medium/RGB12
612
612
612
Full/RGB8
612
520
520
EightyBit/RGB8
612
520
520
37.125MHz
74.25 MHz
84.86 MHz
37.125MHz
74.25 MHz
84.86 MHz
37.125MHz
74.25 MHz
84.86 MHz
37.125MHz
74.25 MHz
84.86 MHz
37.125MHz
74.25 MHz
84.86 MHz
37.125MHz
74.25 MHz
84.86 MHz
ClConfiguration/
PixelFormat
CameraLink Clock
Frequency
Sensor_H_Max
Calculate the CL_H_Count_Max using the following formulas.
CL_H_Count_Max =
Roundup( (Width / Pack Value) + 4 ) × 74.25MHz / CameraLink Clock Frequency, 0 )
1
1
1
2
2
2
1
1
1
1
1
1
8/3
(2.667)
Pack Value
8/3
(2.667)
8/3
(2.667)
10/3
(3.333)
10/3
(3.333)
10/3
(3.333)