—
64
—
AP-
16
00T-
PMCL
Item
Setting range
Default value
Description
PulseGeneratorLength
1 to 1048575
30000
Set the maximum count-up value as
a clock count.
PulseGeneratorLength
(ms)
1 / PulseGeratorClock
(MHz) to 1048575 /
PulseGeneratorClock
(MHz)
66.6667
Set the maximum count-up value in
milliseconds.
This value is calculated using the
[PulseGeneratorLength] value as a
base.
The setting range varies depending
on the [ClockPreScaler] value.
PulseGenerator
Frequency(Hz)
((PulseGeneratorClock
(MHz)) ÷ 1048575) x
1000000 to
(PulseGeneratorClock
(MHz) x 1000000)
15
Set the maximum count-up value as
a frequency.
This value is calculated using the
[PulseGeneratorLength] value as a
base.
PulseGeneratorStart
Point
0 to 1048574
0
Set the start point of the High
interval as a clock count.
When the counter reaches this
value, the output will be 1.
PulseGeneratorStart
Point(ms)
0 to (1048575 /
PulseGeneratorClock
(MHz))
0
Set the start point of the High
interval in milliseconds.
When the counter reaches this
value, the output will be 1.
The setting range varies depending
on the [ClockPreScaler] value.
PulseGeneratorEnd
Point
1 to 1048575
15000
Set the start point of the Low
interval as a clock count.
When the counter reaches this
value, the output will be 0.
PulseGeneratorEnd
Point(ms)
(1 /
PulseGeneratorClock
(MHz)) to (1048575 /
PulseGeneratorClock
(MHz))
33.3333
Set the start point of the Low
interval in milliseconds.
When the counter reaches this
value, the output will be 0.
The setting range varies depending
on the [ClockPreScaler] value.
PulseGeneratorPulse
width(ms)
–
33.3333
Display the High interval width of
the pulse in milliseconds.
The duration between the Start
Point and End Point is calculated.
The setting range varies depending
on the [ClockPreScaler] value.
PulseGenerator
RepeatCount
0 to 255
0
Set the repeat count for the counter.
When this is set to [0], a free
counter is enabled with no repeat
limit.
PulseGeneratorClear
Activation
Off,
LevelHigh,
LevelLow,
RisingEdge,
FallingEdge
Off
Set the clear signal condition for the
count clear input of the pulse
generator.
PulseGeneratorClear
Source
Low,
High,
AcquisitionTriggerWait,
AcquisitionActive,
FrameTriggerWait,
FrameActive,
ExposureActive,
FVAL,
LVAL,
PulseGenerator0-3,
User Output0-3,
Line5-OptIn1,
Line6-OptIn2,
Nand0Out,
Nand1Out
Low
Select the count clear input signal
source.
[Line4 TTL In] can be used on the
Standard Model.
PulseGeneratorClear
Inverter
True, False
False
Select whether to invert the polarity
of the count clear input signal.
PulseGeneratorClear
SyncMode
AsyncMode,
SyncMode
AsyncMode
Select the sync mode for the count
clear input signal.