Error Status
Description
XX SW1 SW2
XX = number of the bad data object in the APDU;
00 = general error of APDU;
01 = error in the 1
st
data object;
02 = error in the 2
nd
data object; etc.
00 90 00
No error occurred
XX 62 82
Data object XX warning, requested information not available
XX 63 00
No information.
XX 63 01
Execution stooped due to failure in other data object
XX 6A 81
Data object XX not supported
XX 67 00
Data object XX with unexpected length
XX 6A 80
Data object XX with unexpected vale
XX 64 00
Data Object XX execution error (no response from IFD)
XX 64 01
Data Object XX execution error (no response from ICC)
XX 6F 00
Data object XX failed, no precise diagnosis
6.2.10.
PAPDU_TCL_PASS_THRU (T=CL Pass Thru)
This command can be used to send raw data using T=CL protocol to a card. Please refer to the
status words defined by the PICC manufacturer for a description of the status words
Command APDU:
Command
CLA
INS
P1
P2
P3
Data
Pass-through
FF
FE
00
00
Lc
Data
Response APDU:
Data
Status Word
PICC response data
SW1, SW2 (card itself