CLOUD
47
X
0
F
R
EFERENCE
M
ANUAL
80
Output:
For retrieving all settings (0xFE), the output will be:
For retrieving current Power up sequence (0xFF), the output will be:
6.3.5.2. CONTACT_EMV_LOOPBACK
This Escape command lets the host force the firmware to perform an EMV Loop-back
application.
Input:
The input buffer contains the escape code value.
Output
:
Output buffer
NULL
Byte0
Byte 1
Byte2
Value Description
0x00
Starts with Class C voltage.
(1.8V
– 3V – 5V order)
Time
delay
between
resets in milliseconds
Bit Map of all Voltage
Classes
[Bit0
– Class A; Bit1 –
Class B; Bit2
– Class C]
0x01
Starts with Class A voltage.
(5V
– 3V – 1.8V order)
Byte0
Value Description
0x00
Starts with Class C voltage. (1.8V
– 3V – 5V order)
0x01
Starts with Class A voltage. (5V
– 3V – 1.8V order)
Byte0
Escape code(0x05)