9.5.1
Change setup by ESC-sequences.
To change the setup A/B or C in Everest-D, you must create an ASCII file with following syn-
tax:
[ESC][^O][^A]{setup,position0,position1,...,position39},[ESC][^O]
The parameters between {} you could repeate for each setup.
The value between [ ] is the decimal position of the ASCII-code position 1...position39 are the
parameter positions, specified below.
If you do not want to change a setup value stored in Everest-D, you could only specified an x for
that position.
Setup = A for setup A
B for setup B
C for setup C
You could create one file for changing all three setups by separate the sequences with a comma.
See example below.
Save the file in ASCII format and send it to Everest-D.
Example: Change only the Volume for setup A to 3 and only the Impact level to position 5 for
setup B.
The file below change only these two parameters:
[ESC][^O][^A]
a,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,2,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,
b,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,4,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,[ESC][^O]
position 22 = 2 volume 3
position 23 = 4 Impact level 5
[ESC] means that you should write the control code with decimal position 27
[^O] means that you should write the control code with decimal position 15 (SI)
[^A] means that you should write the control code with decimal position 1 (SOH)
Position 0 - Activated braille code.
0 = OWN 1
1 = OWN 2
2 = First braille code in the BRLED list
3 = Second braille code in the BRLED list - and so on until...
18 = Last braille code in the BRLED list
Position 1 - Type of braille code.
0 = Computer
1 = Literary
Position 2 - 6/8 Dot braille.
If activated braille code is COMPUTER you must choose 6 or 8 dots braille code
0 = 6 dots
1 = 8 dots