ERRORREPLY=NO 

Deactivates sending of information 
SMS for each received SMS command, 

which was not executed due to any 
error. 

ERRORREPLY =NO – OK 

Conf 

ERRORREPLY? 

Information message: Request for 
ERRORREPLY settings 

ERRORREPLY =(NO),YES 

Conf 

OUTPUT=REMEMBER 

Output power socket remember it’s 

status after it’s unplugged or central 
power is interrupted 

OUTPUT=REMEMBER – 

OK 

Conf 

OUTPUT=ON 

Output power and microrelay will be 

turned on after it’s unplugged or 
central power is interrupted 

OUTPUT=ON – OK 

Conf 

OUTPUT=OFF 

Output power and microrelay will be 

turned off after it’s unplugged or 
central power is interrupted 

OUTPUT=OFF – OK 

Conf 

OUTPUT? 

 

Information message: Request for 
initial mode configuration of 
output power socket and 
microrelay 

 

OUTPUT=(REM), ON, OFF  Conf 

INPUT=ALARMHIGH 

Detection mode for external detector. 

In this case alarm is generated after 
high voltage is detected. 

INPUT=ALARMHIGH– OK 

Conf 

INPUT=ALARMLOW 

Detection mode for external detector. 

In this case alarm is generated after 
low voltage is detected. 

INPUT=ALARMLOW – OK 

Conf 

INPUT? 

Information message: Request for 
input mode configuration

 

INPUT=DISCONNECTED, 

(CONNECTED) 

Conf 

VERSION 

Request for firmware version 

Ver. 1.0.6 (c) 2008 

Ctrl 

RINGON 

Back call is realized to the number 
of the incoming SMS. Usefull 
feature when using prepaid cards 
to keep card active. 

/no confirmation 

Ctrl 

 

 

If bad command is received, power socket replies with „message – ERROR!“ 

message  

 

Capitals and small alphabets are not recognized in commands 

 

SMS messages longer than 20 characters are automatically ignored 

9. Alarms and microrelay 

9.1 External detector alarms 

External detectors can be used for various alarm detections, for example 
motion, fire, gas, water, opened door/window detection and so on. Detectors 

are connected over 3.5 mm jack. It is possible to use more different detectors 
divide by jack divider, total current shouldn’t be more than 50mA. Only first 
alarm within 60 seconds is indicated. 

 

Command 

Description 

Response 

Type 

ALARMON 

Activated is alarm detection by 
external detectors. 

AlarmOn = OK 
Alarm – NO sensor 

Ctrl

 

ALARMOFF 

Deactivated is alarm detection by 
external detectors. 

AlarmOff = OK 

Ctrl

 

Summary of Contents for IQSW-GSM

Page 1: ...User guide www IQsocket eu Intelligent power sockets IQsockettm WALL IQSW GSM makes your life more comfortable User Guide IQSW GSM documentation v1 1 4 R1 for firmware v1 1 4 ...

Page 2: ...ttings for SMS commands 9 6 2 Confirmation settings for phone calls 9 7 Measuring temperature 9 7 1 Thermostat 10 7 2 Temperature calibration 10 8 Other commands 10 9 Alarms and microrelay 11 9 1 External detector alarms 11 9 2 Temperature alarms 12 9 3 Generated alerts 12 9 4 Alarm logs 13 9 5 External detectors scheme 13 9 6 Microrelay scheme 13 10 Date and time 13 11 Scheduler 14 12 Original se...

Page 3: ...our homes or weekend holiday houses 2 Product description Intelligent power socket IQsocket IQSW GSM helps to control any appliance remotely over GSM network using by mobile phone IQSW GSM is managed by SMS messages or phone call It can work also as a independent thermo regulator because of integrated thermometer which control appliance by turning on off according to preconfigured temperature rule...

Page 4: ...for external detectors generating alarms Microrelay Switched contact by microrelay SIM socket Socket for SIM card Push push type Manual button Used to turn on off output power socket manually or reset product to default values Temperature sensor Provides temperature data Detail of temperature sensor Temperature sensor measure environmental temperature and provide it over SMS on request Output powe...

Page 5: ...into wall socket 230V Indicators will start blinking in few seconds then basic test is started for 10 seconds If all is OK red POWER indicator is turned on GSM indicator is blinking periodically green light while searching GSM networks after it s logged blinking every 3 seconds RELAY indicator should light on off if output power socket in turned on off Product is ready now for your use 4 Managing ...

Page 6: ...cket and microrelay are turned off TurnedOFF Ctrl TURNON Output power socket and microrelay are turned on TurnedON Ctrl TURNOFF1 Output power socket is turned off TurnedOFF1 Ctrl TURNON1 Output power socket is turned on TurnedON1 Ctrl TURNOFF2 Microrelay is turned off TurnedOFF2 Ctrl TURNON2 Microrelay is turned on TurnedON2 Ctrl TURNOFF 123 Output power socket is turned off for 123 minutes Maxima...

Page 7: ...ARTTIME XX OK Conf RESTARTTIME Information message Request for RESTARTTIME configuration parameter RESTARTTIME 30 seconds Conf 4 3 Controlling output power socket manually Output power socket can be managed also manually by hidden button on bottom side near the SIM slot Button can be activated by suitable thin mechanic tool Pressing this button causes switching output power socket to negative valu...

Page 8: ...PIN xxxx OK Conf SMSPIN NOPIN Using of password SMSPIN is deactivated SMSPIN NOPIN OK Conf SMSPIN Request for SMSPIN configuration SMSPIN NOPIN 1234 Conf SMSWWW YES Controlling by SMS from Internet is allowed SMSWWW YES OK Conf SMSWWW NO Controlling by SMS from Internet is disabled SMSWWW NO OK Conf SMSWWW Request for SMSWWW configuration SMSWWW NO Y ES Conf 5 2 Security list Security list allow c...

Page 9: ...turned on for all SMS commands SMSCONFIRM YES OK Conf SMSCONFIRM NO SMS confirmation is turned off for all SMS commands SMSCONFIRM NO OK Conf SMSCONFIRM Request for SMS confirmation settings SMSCONFIRM NO Y ES Conf 6 2 Confirmation settings for phone calls Command Description Response Type RINGCONFIRM YES Phone call confirmation is turned on for all commands Hang off after 10 seconds RINGCONFIRM Y...

Page 10: ...on when temperature is below 20 C and deactivating when temperature is over 25 C THERMOSTAT YES TEMPON 20 TEMPOFF 25 Other example is airconditioning activation over 28 C and deactivation when temperature is below 24 C THERMOSTAT YES TEMPON 28 TEMPOFF 24 7 2 Temperature calibration Measured temperature is usually influenced by heating caused by IQsocket electronics so built in thermometer provides...

Page 11: ...In this case alarm is generated after low voltage is detected INPUT ALARMLOW OK Conf INPUT Information message Request for input mode configuration INPUT DISCONNECTED CONNECTED Conf VERSION Request for firmware version Ver 1 0 6 c 2008 Ctrl RINGON Back call is realized to the number of the incoming SMS Usefull feature when using prepaid cards to keep card active no confirmation Ctrl If bad command...

Page 12: ...erature alarms are disabled TEMPALARM NO OK Ctrl TEMPALARM MAX In case of maximal temperature threshold is reached SMS is sent TEMPALARM MAX OK Ctrl TEMPALARM MIN In case of minimal temperature threshold is reached SMS is sent TEMPALARM MIN OK Ctrl TEMPALARM MIX In case of mini or maximal temperature threshold is reached SMS is sent TEMPALARM MIX OK Ctrl TEMPALARM Request for temperature configura...

Page 13: ...Command Description Response Type SHOWALARM Used to list alarm history log yy mm dd hh ss Ctrl This feature can be also used for example to monitor people activity in room In case of active ALARMON you can also switch to ALARMOFF by manual button on device After this manual command you can use manual button under normal operation not switching back to ALARMON More detectors can be used in parallel...

Page 14: ...off INF status of IQsocket is sent as by STATUS command AON Alarm On AOF Alarm Off Examples SCHEDULER 10 00 ON Every day at 10 00 is output power socket turned on SCHEDULER 14 30 OFF Every day at 14 30 is output power socket turned off SCHEDULER 01 00 1 AON Every Monday at 01 00 is activated alarm SCHEDULER 02 00 2 AOF Every Tuesday at 02 00 is deactivated alarm SCHEDULER 18 00 5 INF Every Friday ...

Page 15: ...indicators POWER LIGHTS RED Input power is OK BLINKS RED 4 x WITHIN SECOND Alarm detection is active LIGHTS GREEN Alarm is detected while detection is active BLINKS GREEN 4 x WITHIN SECOND Alarm is detected detection is not active BLINKS RED 2 x PER SECOND SIM is not correctly inserted or missing GSM BLINKS GREEN EACH 3 SECONDS Logged to GSM network BLINKING GREEN EACH SECOND Not logged to GSM net...

Page 16: ...te power turnon turnoff of output circuit up to 48V Remote power turnoff for specified time Remote appliance restart Remote appliance status switch turnon to turnoff or back Remote temperature measuring Thermometer Alarm detection Scheduler Power 230V CEE 7 7 Weight Netto Brutto 350g 420g Operating temperature 10 to 50 C 16 Care and security recommendations Product was designed for indoor use Don ...