Chapter 2 Diagonostic Codes
2-21
F11
Error in expression
mod C3, user Interface : Communication Error between balancing kernel and
user interface (BK -> uI). This error can be cleared
by pressing STOP or Escape.
This error can caused by a bad connection of the RS2
-
32-E serial line. Check external and internal cabling.
F12
Overflow
mod 41, ASS : Too many time clients
mod 44, SAPE : Overflow (e.g. invalid time period)
F13
Not implemented
F14
Read only
F15
Bad line
F16
Bad data type
F17
Not running (still not initialised)
This error can occur after a measuring run, if the incre-
mental encoder of the power clamp is not able to de
-
tect the reference mark (810F17). Please check the
incremental encoders
with C54, C74 (main shaft) and C98 (power clamp)
F18
Timeout
mod 31, Watchdog: Recorded during start-up: Watchdog causes last reset.
Please check error record (C28).
mod 42, Data cond. : Can’t get data from external AD converter
This error can caused by
- a malfunction of the incremental encoder.
Please check C74 and C54.
- a malfunction of the micro-controller board
Check C75 if ADE1 and ADE2 displays valid results.
mod 44, SAPE : Communication timeout (No answer from AWP)
mod C1, Self-test : Self-test failed, test function does not response (timed
out)
F20
Access denied
mod 49, Drive system : Access denied : e.g.
- use of the clamp device if it is not available
(not a power clamp machine?)
- Requested action not allowed
50
uT_CmPLX_ERROR_matrixSingular
60
ERR_vOLTAGE_ZERO
61
ERR_vOLTAGE_BELOW_LImIT
63
ERR_vOLTAGE_ABOvE_LImIT
64
ERR_vOLTAGE_really_HIGH
100
Keyboard : No time client available
101
ERROR_KEyB_NO_HARDWARE_AvAILABLE
102
ERROR_KEyB_ORDER_BuSy
120
Display (Digital) : No Hardware available
Summary of Contents for EEWB304B