OUTPut Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
OUTP:EXT:LOG
Sets the logic used to control the turning of output on and off using an external
contact.
This command is invalid while a sequence is running.
Command
OUTPut:EXTernal:LOGic <character>
OUTPut:EXTernal:LOGic?
Parameter
Value:
LOW
The output is turned on with a low signal (default).
HIGH
The output is turned on with a high-level signal or open
circuit.
(Example)
OUTP:EXT:LOG HIGH
Response
Returns the logic used to control the turning of output on and off using an external
contact in CHAR format in response to OUTP:EXT:LOG?.
OUTP:PON
Sets the output state at power-on.
Command
OUTPut:PON[:STATe] <character>
OUTPut:PON[:STATe]?
Parameter
Value:
SAFE
The output is off. (default)
AUTO
The PWR-01 turns on in the previous power-off state.
FORCe The output is on.
(Example)
OUTP:PON AUTO
Response
Returns the output state at power-on in character format in response to OUT-
P:PON:STAT?.