STATus Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
STAT:QUES:INST:ISUM<n>:PTR
Sets the positive transition of the QUEStionable:INSTrument:ISUMmary<n> sub-
register.
Use <n> to specify the channel number.
For example, to specify channel 2, send the "STAT:QUES:INST:ISUM2:PTR" com-
mand.
Command
STATus:QUEStionable:INSTrument:ISUMmary<n>:PTRansition <NR1>
STATus:QUEStionable:INSTrument:ISUMmary<n>:PTRansition?
Parameter
Value:0 to 32767
Response
Returns the positive transition of the QUEStionable:INSTrument:ISUMmary<n>
subregister in NR1 format.
Preset status
STAT:PRES
Resets the ENABle, PTRansition, and NTRansition filter registers of all status reg-
isters (including sub registers) to their default values. 32 bits registers are used by
the multichannel function.
Default values (16 bits register):
STATus:ENABle = 0x0000
STATus:PTRansition = 0x7FFF
STATus:NTRansition = 0x0000
Default values (32 bits register):
STATus:ENABle = 0x7FFFFFFF
STATus:PTRansition = 0x7FFFFFFF
STATus:NTRansition = 0x00000000
Command
STATus:PRESet