PROGram Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
OUTP:TRIG:STAT
Sets whether to output a trigger signal when the output is turned on.
Command
OUTPut:TRIGger:STATe <boolean>
OUTPut:TRIGger:STATe?
Parameter
Value:
ON(1)
Output
OFF(0) Not output (default)
(Example)
OUTP:TRIG:STAT ON
Response
Returns whether a trigger signal is output when the output is turned on in NR1
format in response to OUTP:TRIG:STAT?.
PROGram Command
The sequence function is mapped to the PROGram trigger subsystem.
A single program consisting of up to 64 steps (indexes 0 to 63) can be created.
The sequence content is retained even when the power is turned off.
Sequence creation and editing commands are invalid while a sequence is running.
Program template
The contents of a program template can be reflected in the initial step of a newly
created program (PROG:CRE).
The contents of a template can be changed while a program is running.
The settings of a program template cannot be saved.
The settings do not change even when you send a *RST or *RCL command. The
contents returned to their default values when the PWR-01 is restarted.