55

Switch(config-if)# description this is the VLAN 2 
 
Switch(config-if)# no description  ->Delete the description. 

IP address of the VLAN 

Switch(config)# interface vlan 2 
Switch(config-if)# 
Switch(config-if)# ip address 192.168.10.18/24 
 
Switch(config-if)# no ip address 192.168.10.8/24  ->Delete 
the IP address 

Create multiple VLANs 
(VLAN 5-10) 

Switch(config)# interface vlan 5-10 

Shut down VLAN 

Switch(config)# interface vlan 2 
Switch(config-if)# shutdown 
 
Switch(config-if)# no shutdown    ->Turn on the VLAN 
 

Display – VLAN table 

Switch# sh vlan 

VLAN Name      Status    Trunk Ports                    Access Ports 

----  ------------  -------   --------------------------  -------------------------- 

1        VLAN1      Static                -                            fa1-7,gi8-10 

2        VLAN2      Unused            -                                      - 

3    test      Static     fa4-7,gi8-10       fa1-3,fa7,gi8-10

                   

Display – VLAN 
interface information 

Switch# show interface vlan1 

interface vlan1 is up, line protocol detection is disabled 
    index 14 metric 1 mtu 1500 <UP,BROADCAST,RUNNING,MULTICAST> 
  HWaddr: 00:12:77:ff:01:b0 
    inet 192.168.10.100/24 broadcast 192.168.10.255 
        input packets 639, bytes 38248, dropped 0, multicast packets 0 
        input errors 0, length 0, overrun 0, CRC 0, frame 0, fifo 0, missed 0 
        output packets 959, bytes 829280, dropped 0 
        output errors 0, aborted 0, carrier 0, fifo 0, heartbeat 0, window 0 
    collisions 0

 

Management VLAN 

Management VLAN 

JetNet 5008G-P(config)# int vlan 1 (Go to management 
VLAN) 
JetNet 5008G-P(config-if)# no shutdown 

Display 

JetNet 5008G-P# show running-config 
…. 


interface vlan1 
  ip address 192.168.10.17/24 
 ip igmp 

 no shutdown 


…. 

 

 

Summary of Contents for JetNet 5008G-P Series

Page 1: ...1 Korenix JetNet 5008G P Series Industrial Managed Ethernet Switch User s Manual Version V1 0 Sep 2007 www korenix com ...

Page 2: ...t 5008G P Series Industrial Managed Ethernet Switch User s Manual Copyright Notice Copyright 2006 Korenix Technology Co Ltd All rights reserved Reproduction in any form or by any means without permission is prohibited ...

Page 3: ...reparation for Telnet Console 8 4 Feature Configuration 11 4 1 Command Line Interface Introduction 12 4 2 Basic Setting 17 4 3 Port Configuration 32 4 4 Network Redundancy 39 4 5 VLAN 49 4 6 Traffic Prioritization 56 4 7 Multicast Filtering 61 4 8 SNMP 64 4 9 Security 68 4 10 Warning 74 4 11 Monitor and Diag 79 4 12 Save to Flash 85 4 13 Logout 86 5 Appendix 87 5 1 Product Specification 87 5 2 Kor...

Page 4: ...100FX and Gigabit Fiber This is Korenix patented ring technology which is registered in most countries For interoperability with your existed network JetNet 5008G P series also come with an advanced redundant network solution Ring Coupling and Dual Homing II technology With Ring Coupling technology Ethernet Ring can be extended Dual Homing II technology allows you to enable Rapid Super Ring and st...

Page 5: ...JetView for network Management Redundant DC Power Inputs 1 5KV Hi Pot Protection for ports and power Industrial Heat dispersing design 10 70 C operating temperature Rigid Aluminum Case Complies with IP31 Note The detail spec is listed in Appendix 5 1 1 3 Package List Korenix JetNet 5008G P Series products are shipped with following items One industrial Managed Ethernet switch Documentation and Sof...

Page 6: ... information Following topics are covered in this chapter 2 1 Hardware Introduction Dimension Structure View 2 2 Wiring Power Inputs 2 3 Wiring Ethernet Ports 2 4 Wiring Combo Ports 2 1 Hardware Introduction Dimension JetNet 5008G P Industrial Gigabit Switch dimension W x H x D is 140mm x 30mm x200mm ...

Page 7: ...nt DC wires from being loosened 3 Power 1 and Power 2 support power redundancy and polarity reverse protection functions 4 Positive and negative power system inputs are both accepted but Power 1 and Power 2 must apply the same mode Note1 It is a good practice to turn off input and load power and to unplug power terminal block before making wire connections Otherwise your screwdriver blade can inad...

Page 8: ...ched device The LNK LED will light up when the cable is correctly connected Refer to the LED Indicators section for descriptions of each LED indicator Always make sure that the cables between the switches and attached devices e g switch hub or workstation are less than 100 meters 328 feet The wiring cable types are as below 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100 Base ...

Page 9: ...k Before you attempt to use the embedded web interface to manage switch operation verify that your JetNet 5008G P Series Industrial Ethernet Switch is properly installed on your network and that every PC on this network can access the switch via the web browser 1 Verify that your network interface card NIC is operational and that your operating system supports TCP IP protocol 2 Wire DC power to th...

Page 10: ...e Web UI connection session of JetNet 5008G P will be logged out automatically if you don t give any input after 30 seconds After logged out you should re login and key in correct user name and password again 3 1 2 Secured Web Interface Korenix web management page also provides secured management HTTPS login All the configuration commands will be secured and will be hard for the hackers to sniff t...

Page 11: ...face will then appear 7 Once you enter the web based management interface all the commands you see are the same as what you see by HTTP login 3 2 Preparation for Telnet Console 3 2 1 Telnet Korenix JetNet 5008G P supports Telnet console You can connect to the switch by Telnet and the command lines are the same as what you see by RS232 console port Below are the steps to open Telnet connection to t...

Page 12: ...with the switch you should download the SSH client tool first SSH Client There are many free sharewares trials or charged SSH clients you can find on the internet Fox example PuTTY is a free and popular Telnet SSH client We ll use this tool to demonstrate how to login JetNet by SSH Note PuTTY is copyright 1997 2006 Simon Tatham Download PuTTY http www chiark greenend org uk sgtatham putty download...

Page 13: ...ept the Security Alert 3 After few seconds the SSH connection to JetNet 5008G P is opened You can see the login screen as the below figure 4 Type the Login Name and its Password The default Login Name and Password are admin admin 5 All the commands you see in SSH are the same as the CLI commands you see via Telnet The next chapter will introduce in detail how to use command line to configure the s...

Page 14: ...net console Korenix web management page is developed by JAVA It allows you to use a standard web browser such as Microsoft Internet Explorer or Mozila to configure and interrogate the switch from anywhere on the network Note IE 5 0 or later versions do not allow Java applets to open sockets by default Users have to directly modify the browser settings to selectively enable Java applets to use netw...

Page 15: ... configuration mode Type configure terminal to enter next mode exit to leave to see the command list JN5008G P enable Turn on privileged mode command exit Exit current mode and down to previous mode list Print command list ping Send echo messages quit Exit current mode and down to previous mode show Show running system information telnet Open a telnet connection traceroute Trace route to destinati...

Page 16: ...erminal Switch config access list Add an access list entry administrator Administrator account setting arp Set a static ARP entry clock Configure time of day clock default Set a command to its defaults end End current mode and change to enable mode exit Exit current mode and down to previous mode gvrp GARP VLAN Registration Protocol hostname Set system s network name interface Select an interface ...

Page 17: ...face Switch config interface fa1 Switch config if acceptable Configure 802 1Q acceptable frame types of a port auto negotiation Enable auto negotiation state of a given port description Interface specific description duplex Specify duplex mode of operation for a port end End current mode and change to enable mode exit Exit current mode and down to previous mode flowcontrol Set flow control value f...

Page 18: ...global configuration command Switch Global configuration In global configuration mode you can configure all the features that the system provides you Enter Type configure terminal in privileged EXEC mode Exit Type exit or end or press Ctrl Z to exit Next mode Type interface IFNAME VLAN VID to enter interface configuration mode Switch config Port Interface configuration In this mode you can configu...

Page 19: ...shed command Ctrl S To lock the screen of the terminal You can t input any command Ctrl Q To unlock the screen which is locked by Ctrl S Ctrl Z To exit configuration mode Alert message when multiple users want to configure the switch If the administrator is in configuration mode then the Web users can t change the settings JetNet 5008G P allows only one administrator to configure the switch at a t...

Page 20: ...tion reload factory default and reboot the system Following commands are included in this group 4 2 1 Switch Setting 4 2 2 Admin Password 4 2 3 IP Configuration 4 2 4 Time Setting 4 2 5 Backup and Restore 4 2 6 Firmware Upgrade 4 2 7 Factory Default 4 2 8 System Reboot 4 2 1 Switch Setting You can assign System name Location Contact and view system information Figure 4 2 1 1 Web UI of the Switch S...

Page 21: ...path to find its private MIB in MIB browser Note When you attempt to view private MIB you should compile private MIB files into your MIB browser first System Description JetNet 5008G P Industrial Management Ethernet Switch is the name of this product Firmware Version Display the firmware version installed in this device MAC Address Display unique hardware address MAC address assigned by the manufa...

Page 22: ...address settings DHCP Client You can select to Enable or Disable DHCP Client function When DHCP Client function is enabled an IP address will be assigned to the switch from the network s DHCP server In this mode the default IP address will therefore be replaced by the one assigned by DHCP server If DHCP Client is disabled then the IP address that you specified will be used instead IP Address You c...

Page 23: ...ly to apply your configuration 4 2 4 Time Setting Time Setting source allow user to set the time manually or through NTP server Network Time Protocol NTP is used to synchronize computer clocks on the internet You can configure NTP settings here to synchronize the clocks of several switches on the network JetNet5008G P also provides Daylight Saving function Manual Setting User can select Manual set...

Page 24: ...nland 22 GMT 02 00 Mid Atlantic 23 GMT 01 00 Azores 24 GMT 01 00 Cape Verde Is 25 GMT Casablanca Monrovia 26 GMT Greenwich Mean Time Dublin Edinburgh Lisbon London 27 GMT 01 00 Amsterdam Berlin Bern Rome Stockholm Vienna 28 GMT 01 00 Belgrade Bratislava Budapest Ljubljana Prague 29 GMT 01 00 Brussels Copenhagen Madrid Paris 30 GMT 01 00 Sarajevo Skopje Sofija Vilnius Warsaw Zagreb 31 GMT 01 00 Wes...

Page 25: ... Aukland Wellington 73 GMT 12 00 Fiji Kamchatka Marshall Is 74 GMT 13 00 Nuku alofa Daylight Saving Time Set when Enable Daylight Saving Time start and end During the Daylight Saving Time the device s time is one hour earlier than the actual time Once you finish your configuration click on Apply to apply your configuration 4 2 5 DHCP Server You can select to Enable or Disable DHCP Server function ...

Page 26: ...s a MAC address and IP address binding and removing function You can type in the specified IP and MAC address then click Add to add a new MAC IP address binding rule for a specified link partner like PLC or any device without DHCP client function To remove from the binding list just select the rule to remove and click Remove DHCP Leased Entries JetNet 5008G P provides an assigned IP address list f...

Page 27: ...ode can be used in both CLI and Web UI TFTP Server IP Address You need to key in the IP address of your TFTP Server here Backup Restore File Name System uses default file name Configuration File The configuration file of the switch is a pure text file You can open it by word txt read file You can also modify the file add remove the configuration settings and then restore back to the switch Startup...

Page 28: ...erver IP Then click on Backup Restore 4 2 7 Firmware Upgrade In this section you can update the latest firmware for your switch Korenix provides the latest firmware in Korenix Web site The new firmware may include new features bug fixes or other software changes We ll also provide the release notes for the update as well For technical viewpoint we suggest you use the latest firmware before install...

Page 29: ...le to restore the configuration back to the switch This mode is only provided by Web UI while CLI is not supported TFTP Server mode In this mode the switch acts as the TFTP client Before you do so make sure that your TFTP server is ready And then please type the IP address of TFTP Server IP address This mode can be used in both CLI and Web UI TFTP Server IP Address You need to key in the IP addres...

Page 30: ... will copy the firmware file and replace the firmware in the flash The CLI show until the process is finished 4 2 8 Factory Default In this section you can reset all the configurations of the switch to default setting Click on Reset the system will then reset all configurations to default setting The system will show you popup message window after finishing this command Default setting will work a...

Page 31: ... other IP address when you use this command by CLI and Web UI our software will not reset the IP address to default IP The system will remain the IP address so that you can still connect the switch via the network 4 2 9 System Reboot System Reboot allows you to reboot the device Some of the feature changes require you to reboot the system Click on Reboot to reboot your device Note Remember to clic...

Page 32: ...igure 4 2 8 3 Popup message screen appears when rebooting the switch 4 2 10 CLI Commands for Basic Setting Feature Command Line Switch Setting System Name Switch config hostname WORD Network name of this system Switch config hostname JN5008G P JN5008G P config System Location JN5008G P config snmp server location Taipei ...

Page 33: ...trator Administrator account information name orwell password orwell IP Configuration IP Address Mask 192 168 10 8 255 255 255 0 JN5008G P config int vlan 1 JN5008G P config if ip address 192 168 10 8 24 Gateway JN5008G P config ip route 0 0 0 0 0 192 168 10 254 24 Remove Gateway JN5008G P config no ip route 0 0 0 0 0 192 168 10 254 24 Display JN5008G P show running config interface vlan1 ip addre...

Page 34: ...er to 4 12 to see how to save settings to the flash Note 2 192 168 10 33 is the TFTP server s IP Your environment may use different IP addresses Please type target TFTP server IP in this command Restore Configuration Switch copy tftp 192 168 10 33 startup config Show Startup Configuration Switch show startup config Show Running Configuration Switch show running config Firmware Upgrade Firmware Upg...

Page 35: ...ation speed duplex and flow control Select the port you want to configure and make changes to the port In State column you can enable or disable the state of this port Once you disable the port stop to link to the other end and stop to forward any traffic The default setting is Enable which means all the port are workable when you receive the device In Speed Duplex column you can configure port sp...

Page 36: ...s click on Apply to save the configuration Technical Tips If both ends are not at the same speed they can t link with each other If both ends are not in the same duplex mode they will be connected by Half mode 4 3 2 Port Status Port Status shows you current port status The description of the columns is as below Port Port interface number Type 100Base TX Fast Ethernet port 1000Base TX Gigabit Ether...

Page 37: ...imits at each port and even apply the limit to certain packet types as described below Packet type You can select the packet type that you want to filter The packet types of the Ingress Rule listed here include Broadcast Only Broadcast multicast Broadcast Multicast UnknownUnicast and All The packet types of the Egress Rule outgoing only support All packet types Rate This column allows you to manua...

Page 38: ...re some different descriptions for the port trunking Different manufacturers may use different descriptions for their products like Link Aggregation Group LAG Link Aggregation Control Protocol Ethernet Trunk EtherChannel etc Most of the implementations now conform to IEEE standard 802 3ad The aggregated ports can interconnect to the other switch which also supports Port Trunking Korenix Supports 2...

Page 39: ... need here Aggregation Status This page shows the status of port aggregation Once the aggregation ports are negotiated well you will see following status Group ID Display Trunk 1 to Trunk 5 set up in Aggregation Setting Type Static or LACP set up in Aggregation Setting Aggregated When LACP links well you can see the member ports in Aggregated column Individual When LACP is enabled member ports of ...

Page 40: ...duplex full Port1 Link Change to DOWN set the duplex mode ok Switch config if Port1 Link Change to UP Port Control Flow Control Switch config if flowcontrol on Flowcontrol on for port 1 set ok Switch config if flowcontrol off Flowcontrol off for port 1 set ok Port Status Port Status Switch show interface fa1 Interface fastethernet1 Administrative Status Enable Operating Status Connected Duplex Ful...

Page 41: ...gabits per second 0 is no limit JetNet 5008G P config if rate limit ingress bandwidth 8 Set the ingress rate limit 8Mbps for Port 1 Port Trunking LACP JetNet 5008G P config lacp group 1 gi8 10 Group 1 based on LACP 802 3ad is enabled Note The interface list is fa1 fa3 5 gi8 10 Static Trunk JetNet 5008G P config trunk group 2 fa6 7 Trunk group 2 enable ok Display LACP etNet 5008G P show lacp intern...

Page 42: ...dard includes 802 1D 1998 STP 802 1w RSTP Following commands are included in this group 4 4 1 RSTP 4 4 2 RSTP Info 4 4 3 Rapid Super Ring 4 4 4 Ring Info 4 4 1 RSTP RSTP is the abbreviation of Rapid Spanning Tree Protocol If a switch has more than one path to a destination it will lead to message loops that can generate broadcast storms and quickly bog down a network The spanning tree was created ...

Page 43: ...riority the bridge with the lowest MAC address will then become the root bridge Note The bridge priority value must be in multiples of 4096 A device with a lower number has a higher bridge priority Ex 4096 is higher than 32768 Max Age 6 40 Enter a value from 6 to 40 seconds here This value represents the time that a bridge will wait without receiving Spanning Tree Protocol configuration messages b...

Page 44: ... from the transmitting bridge at the specified port Priority Enter a value between 0 and 240 using multiples of 16 This is the value that decides which port should be blocked by priority in a LAN Admin P2P Some of the rapid state transitions that are possible within RSTP depend upon whether the port of concern can only be connected to another bridge i e it is served by a point to point LAN segment...

Page 45: ...Ring and Rapid Super Ring technology Super Ring is Korenix 1st generation ring redundancy technology released with JetNet 4000 and 4500 series managed switches Rapid Super Ring is Korenix 2nd generation Ring redundancy technology This is Korenix pattern and protected in countries all over the world The Rapid Super Ring has enhanced Ring Master selection and shorted recovery time This page allows y...

Page 46: ...topology change the ring master will automatically change the blocking port to forwarding so that the traffic transmitting will not be terminated Not like JetNet 4000 4500 series there is no additional DIP switch to enable R M in JetNet 5008G P The Ring Master of JetNet 5008G P is automatically selected by the RSR engine The parameter Priority is provided to change the Ring Master if need Priority...

Page 47: ...of Rapid Super Ring Dual Homing II Dual Homing II is the important feature of Korenix 2nd generation Ring redundancy technology When you want to connect multiple RSR or form redundant topology with other vendors Dual Homing II allows you to enable RSTP and RSR from one device at the same Thus you have more flexibility and standard RSTP way to construct your network topology As what is shown in the...

Page 48: ...reely connect 2 or more Rapid Super Rings Note These are no commands to enable Auto Ring Coupling Just need to enable RSTP and Dual Homing II at the same device Also the path paths between the 2 Coupling switches should not be the blocking path 4 4 4 Ring Info This page shows you RSR information Protocol Status Enable or Disable Ring Status Normal State means the switch is running Rapid Super Ring...

Page 49: ...nfig if spanning tree cost 1 200000000 16 bit based value range from 1 65535 32 bit based value range from 1 200 000 000 JetNet 5008G P config if spanning tree cost 200000 Port Priority JetNet 5008G P config if spanning tree port priority 0 240 Number from 0 to 240 in multiple of 16 JetNet 5008G P config if spanning tree port priority 128 Link Type Auto JetNet 5008G P config if spanning tree link ...

Page 50: ... admin link type Auto Rapid Spanning Tree oper link type Point to Point Rapid Spanning Tree admin edge port Enabled Rapid Spanning Tree oper edge port Edge Port 128 6 as Designated Role is in Forwarding State Port Path Cost 200000 Port Identifier 128 6 Designated root has priority 32768 address 0012 7700 0112 Designated bridge has priority 32768 address 0012 77ff 0510 Designated Port ID is 128 6 R...

Page 51: ...al state Role type Redundancy Manager Protocol Version 2 Ring Port fa1 fa2 Switch Priority 100 Hello time 1000 msec Operate hello time 1000 msec Dual Homing II status Enable Super Ring Statistics of Switch WPDU sent 0 received 0 TCN sent 0 received 0 Ring State Transmit count 0 Role Type Transmit count 3 ...

Page 52: ... across different switches see Figure 1 IEEE 802 1Q tag based VLAN makes use of VLAN control information stored in a VLAN header attached to IEEE 802 3 packet frames This tag contains a VLAN Identifier VID that indicates which VLAN a frame belongs to Since each switch only has to check a frame s tag without the need to dissect the contents of the frame this also saves a lot of computing resources ...

Page 53: ...gged and untagged packets Tag Only mode means that the port can only accept tagged packets Ingress Filtering Ingress filtering helps VLAN engine to filter out undesired traffic on a port When Ingress Filtering is enabled the port checks whether the incoming frames belong to the VLAN they claimed or not Then the port determines if the frames can be processed or not For example if a tagged frame fro...

Page 54: ...ANs The available character is 12 for you to input If you don t input VLAN name the system will automatically assign VLAN name for the VLAN The rule is VLAN VLAN ID Figure 4 5 2 2 The steps to create a new VLAN Type VLAN ID and NAME and press Add to create a new VLAN Then you can see the new VLAN in the Static VLAN Configuration table Refer to Figure 4 5 2 3 After created the VLAN the status of th...

Page 55: ... not configured now Figure 4 5 2 4 Configure Egress rule of the ports Not available U Untag Indicates that egress outgoing frames are not VLAN tagged T Tag Indicates that egress outgoing frames are to be VLAN tagged Steps to configure Egress rules Select the VLAN ID Entry of the selected VLAN turns to light blue Assign Egress rule of the ports to U T Press Apply to apply the setting If you want to...

Page 56: ...and VLAN table display Feature Command Line VLAN Port Configuration VLAN Port PVID Switch config if switchport trunk native vlan 2 Set port default vlan id to 2 success Port Accept Frame Type JetNet 5008G P config inter fa1 JetNet 5008G P config if acceptable frame type all any kind of frame type is accepted JetNet 5008G P config if acceptable frame type vlantaggedonly only vlan tag frame is accep...

Page 57: ...1 switchport access vlan 1 switchport access vlan 3 switchport trunk native vlan 2 interface vlan1 ip address 192 168 10 8 24 no shutdown VLAN Configuration Create VLAN 2 Switch config vlan 2 vlan 10 success Switch config interface vlan 2 Switch config if Note In CLI configuration you should create a VLAN interface first Then you can start to add remove ports Default status of the created VLAN is ...

Page 58: ...VLAN2 Unused 3 test Static fa4 7 gi8 10 fa1 3 fa7 gi8 10 Display VLAN interface information Switch show interface vlan1 interface vlan1 is up line protocol detection is disabled index 14 metric 1 mtu 1500 UP BROADCAST RUNNING MULTICAST HWaddr 00 12 77 ff 01 b0 inet 192 168 10 100 24 broadcast 192 168 10 255 input packets 639 bytes 38248 dropped 0 multicast packets 0 input errors 0 length 0 overrun...

Page 59: ...fic of your industrial network Following commands are included in this group 4 6 1 QoS Setting 4 6 2 CoS Queue Mapping 4 6 3 DSCP Queue Mapping 4 6 1 QoS Setting Queue Scheduling You can select the Queue Scheduling rule as follows Use an 8 4 2 1 weighted fair queuing scheme This is also known as WRR Weight Round Robin JetNet will follow 8 4 2 1 rate to process the packets in a queue from the highe...

Page 60: ...m will provide default COS Queue table to which you can refer for the next command After configuration press Apply to enable the settings 4 6 2 CoS Queue Mapping This page is to change CoS values to Physical Queue mapping table Since the switch fabric of JetNet only supports 4 physical queues Lowest Low Middle and High Users should therefore assign how to map CoS value to the level of the physical...

Page 61: ...oritization Command Lines of the Traffic Prioritization configuration Feature Command Line QoS Setting Queue Scheduling Strict Priority JetNet 5008G P config qos queue sched sp Strict Priority wrr Weighted Round Robin Use an 8 4 2 1 weight JetNet 5008G P config qos queue sched sp cr Queue Scheduling WRR JetNet 5008G P config qos queue sched wrr Port Setting CoS Default Port Priority JetNet 5008G P...

Page 62: ...ighted Round Robin Use an 8 4 2 1 weight Display Port Setting Trust Mode JetNet 5008G P show qos trust QoS Port Trust Mode Port Trust Mode 1 DSCP first 2 COS only 3 COS only 4 COS only 5 COS only 6 COS only 7 COS only 8 COS only 9 COS only 10 COS only Display Port Setting CoS Port Default Priority JetNet 5008G P show qos port cos Port Default Cos Port CoS 1 7 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 CoS Qu...

Page 63: ...CoS Queue mapping JetNet 5008G P sh qos cos map CoS to Queue Mapping CoS Queue 0 1 1 0 2 0 3 1 4 2 5 2 6 3 7 3 DSCP Queue Mapping Format JetNet 5008G P config qos dscp map PRIORITY Assign an priority 63 highest JetNet 5008G P config qos dscp map 0 QUEUE Assign an queue 0 3 Format qos dscp map priority_value queue_value Map DSCP 0 to Queue 1 JetNet 5008G P config qos dscp map 0 1 The TOS DSCP to qu...

Page 64: ...o the multicast group Report A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indicated in the report message Leave Group A message sent by a host to the querier to indicate that the host has quit as a member of a specific multicast group You can enable IGMP Snooping and IGMP Query functions here You will see the information of the IGMP ...

Page 65: ...un IGMP Snooping feature in several VLANs you should notice that whether each VLAN has its own IGMP Querier first The IGMP querier periodically sends query packets to all end stations on the LANs or VLANs that are connected to it For networks with more than one IGMP querier a switch with the lowest IP address becomes the IGMP querier In IGMP Query selection you can select V1 V2 or Disable V1 means...

Page 66: ... vlan1 ip igmp is enabled ip igmp version 1 JetNet 5008G P sh ip igmp snooping IGMP snooping is globally enabled Vlan1 is IGMP snooping disabled immediate leave is disabled last member query interval is 100 centiseconds Vlan12 is IGMP snooping disabled immediate leave is disabled last member query interval is 100 centiseconds Display IGMP Table JetNet 5008G P sh ip igmp snooping multicast all VLAN...

Page 67: ... configure SNMP V1 V2c Community The community string can be viewed as the password because SNMP V1 V2c doesn t request you to enter password before you try to access SNMP agent The community includes 2 privileges Read Only and Read and Write With Read Only privilege you only have the ability to read the values of MIB tables Default community string is Public With Read and Write privilege you have...

Page 68: ...e user can select either MD5 Message Digest algorithm 5 or SHA Secure Hash Algorithm MD5 is a widely used cryptographic hash function with a 128 bit hash value SHA Secure Hash Algorithm hash functions refer to five Federal Information Processing Standard approved algorithms for computing a condensed digital representation JetNet 5008G P provides 2 user authentication protocols in MD5 and SHA You w...

Page 69: ...r configuration you can see the change of the SNMP pre defined standard traps and Korenix pre defined traps The pre defined traps can be found in Korenix private MIB 4 8 4 CLI Commands of the SNMP Command Lines of the SNMP configuration Feature Command Line SNMP Community Read Only Community JetNet 5008G P config snmp server community public ro community string add ok Read Write Community JetNet 5...

Page 70: ...SNMP Trap Server IP with version 2 and community JetNet 5008G P config snmp server host 192 168 10 33 version 2 private SNMP trap host add OK Disable SNMP Trap JetNet 5008G P config no snmp server enable trap Set SNMP trap disable ok Display JetNet 5008G P sh snmp server trap SNMP trap Enabled SNMP trap community public JetNet 5008G P show running config snmp server community public ro snmp server...

Page 71: ...ic This is a simple way to secure your network environment and not to be accessed by hackers This page allows you to enable Port Security and configure Port Security entry Port Security State Change Port Security State of the port to Enable first Add Port Security Entry Select the port and type VID and MAC address Format of the MAC address is xxxx xxxx xxxx Ex 0012 7701 0101 Max volume of one port...

Page 72: ...y function Add Security IP You can assign specific IP addresses and then press Add Only these IP addresses can access and manage JetNet via a web browser or Telnet Max security IP is 10 Security IP List This table shows you added security IP addresses You can press Remove to delete Reload to reload the table Once you finish configuring the settings click on Apply to apply your configuration 4 9 3 ...

Page 73: ... switch to server If user select Local for the authentication method switch use the local user data base which can be create in this page for authentication Radius Server IP The IP address of Radius server Shared Key The password for communicate between switch and Radius Server Server Port UDP port of Radius server Accounting Port Port for packets that contain the information of account login or l...

Page 74: ...fail Otherwise the port will be set to Guest VLAN Host Mode if there are more than one device connected to this port set the Host Mode to single means only the first PC authenticate success can access this port If this port is set to multi all the device can access this port once any one of them pass the authentication Control Direction determined devices can send data out only or both send and re...

Page 75: ...table ucast static set ok Port Security JetNet 5008G P config interface fa1 JetNet 5008G P config if switchport port security Disables new MAC addresses learning and aging activities Note Rule Add the static MAC VLAN and Port binding first then enable the port security to stop new MAC learning Disable Port Security JetNet 5008G P config if no switchport port security Enable new MAC addresses learn...

Page 76: ...urity JetNet 5008G P config ip security Set ip security enable ok JetNet 5008G P config ip security host 192 168 10 33 Add ip security host 192 168 10 33 ok Display JetNet 5008G P show ip security ip security is enabled ip security host 192 168 10 33 ...

Page 77: ...d to the overall function of the switch whereas Port Events related to the activity of a specific ports System Event Warning Event is sent when Device Cold Start Power is cut off and then reconnected Device Warm Start Reboot the device by CLI or Web UI Power 1 Failure Power 1 is failure Power 2 Failure Power 2 is failure Authentication failure An incorrect password SNMP Community String is entered...

Page 78: ...In this mode JetNet 5008G P will print the occurred events selected in the Event Selection page to System Log table of JetNet 5008G P You can monitor the system logs in Monitor and Diag Event Log page Remote Mode The remote mode is also known as Server mode in JetNet 4500 series In this mode you should assign the IP address of the System Log server JetNet 5008G P will send the occurred events sele...

Page 79: ...JetNet 5008G P supports E mail Warning feature The switch will send the occurred events to remote E mail server The receiver can then receive notification by E mail The E mail warning is conformed to SMTP standard This page allows you to enable E mail Alert assign the SMTP Server IP Sender E mail Receiver E mail If SMTP server requests you to authorize first you can also set up the username and pa...

Page 80: ...cters Once you finish configuring the settings click on Apply to apply your configuration 4 10 4 CLI Commands Command Lines of the Warning configuration Feature Command Line Event Selection Event Selection JetNet 5008G P config warning event coldstart Switch cold start event warmstart Switch warm start event linkdown Switch link down event linkup Switch link up event all Switch all event authentic...

Page 81: ...l Alert set Server 192 168 10 100 Account admin korenix com ok Receiver mail JetNet 5008G P config smtp server receipt 1 korecare korenix com SMTP Email Alert set receipt 1 korecare korenix com ok Authentication with username and password JetNet 5008G P config smtp server authentication username admin password admin SMTP Email Alert set authentication Username admin Password admin Note You can ass...

Page 82: ... Aging Time can be modified in this page Static Unicast MAC Address In some applications users may need to type in the static Unicast MAC address to its MAC address table In this page you can type MAC Address format xxxx xxxx xxxx select its VID and Port ID and then click on Add to add it to MAC Address table MAC Address Table In this MAC Address Table you can see all the MAC Addresses learnt by t...

Page 83: ...s Note If you see many Bad Abort or Collision counts increased that may mean your network cable is not connected well the network performance of the port is poor etc Please check your network cable Network Interface Card of the connected device the network application or reallocate the network traffic etc Click on Clear Selected to reinitialize the counts of the selected ports and Clear All to rei...

Page 84: ... as Monitor Port These are the ports you want to monitor The traffic of all source monitor ports will be copied to destination analysis ports You can choose a single port or any combination of ports but you can only monitor them in Rx or TX only Click on checkbox of the Port ID RX Tx or Both to select the source ports Destination Port This is also known as Analysis Port You can analyze the traffic...

Page 85: ...y includes the index occurred data and time and content of the events Click on Clear to clear the entries Click on Reload to refresh the table 4 11 5 Ping Utility This page provides Ping Utility for users to ping remote device and check whether the device is alive or not Type Target IP address of the target device and click on Start to start the ping After few seconds you can see the result in the...

Page 86: ...ss table UNICAST MAC ADDRESS Destination Address Address Type Vlan Destination Port 000f b079 ca3b Dynamic 1 fa4 0012 7701 0386 Dynamic 1 fa7 0012 7710 0101 Static 1 fa7 0012 7710 0102 Static 1 fa7 0012 77ff 0100 Management 1 MULTICAST MAC ADDRESS Vlan Mac Address COS Status Ports 1 0100 5e40 0800 0 fa6 1 0100 5e7f fffa 0 fa4 fa6 Show MAC Address Table Dynamic Learnt MAC addresses JetNet 5008G P s...

Page 87: ... JetNet 5008G P config mirror source fa1 2 both Mirror source fa1 2 both set ok Note Select source port list and TX RX Both mode Select Destination Port JetNet 5008G P config mirror destination fa6 both Mirror destination fa6 both set ok Display JetNet 5008G P show mirror Mirror Status Enabled Ingress Monitor Destination Port fa6 Egress Monitor Destination Port fa6 Ingress Source Ports fa1 fa2 Egr...

Page 88: ...the switch without clicking on Save Configuration will cause loss of new settings After selecting Save Configuration click on Save to Flash to save your new configuration Command Lines Feature Command Line Save JN5008G P write Building Configuration OK Switch copy running config startup config Building Configuration OK ...

Page 89: ...on will be logged out if you don t input any command after 30 seconds The Logout command allows you to manually logout the web connection Click on Yes to logout No to go back the configuration page Command Lines Feature Command Line Logout JN5008G P exit JN5008G P exit ...

Page 90: ... with VLAN Tag MAC Address 8K MAC Packet Buffer 1Mbits Transfer performance 14 880pps for Ethernet and 148 800 for Fast Ethernet 1488100 for Gigabit Ethernet Management Configuration Cisco Like CLI Telnet Web JetView TFTP Web Update for firmware and configuration backup and restore DHCP Client Server warm reboot reset to default Admin password Port Speed Duplex Control status statistic MAC address...

Page 91: ...er Ring RSR 2nd generation Korenix Ring Redundancy Technology Failure recovery within 5ms Dual Homing II RSR over RSTP Allows users to enable RSR and RSTP at the same device Auto Ring Coupling Auto Ring Coupling allows users to couple Rapid Super Rings Legacy Super Ring Client mode to backward compatible with Super Ring devices Interface Number of Ports 10 100TX 6 x RJ 45 Auto MDI MDI X Auto Negot...

Page 92: ...nformation JetNet 5008G P Industrial 9 Port Managed Ethernet Switch Includes z 6 ports 10 100Base TX 1 port 10 100 1000Base TX and 2 10 100 1000 RJ 45 SFP Combo ports Switch z Documentation CD ROM 5 2 Korenix SFP family Korenix certificated many types of SFP transceiver These certificated SFP transceivers can be identified by JetNet 5008G P and displayed in the UI The SFP transceivers we certifica...

Page 93: ...wide operating temperature 10 70 SFPGLX10 1000Base LX single mode SFP transceiver 10Km 10 70 SFPGLX10 w 1000Base LX single mode SFP transceiver 10Km wide operating temperature 40 85 SFPGLHX30 1000Base LHX single mode SFP transceiver 30Km 10 70 SFPGLHX30 w 1000Base LHX single mode SFP transceiver 30Km wide operating temperature 40 85 SFPGXD50 1000Base XD single mode SFP transceiver 50Km 10 70 SFPGX...

Page 94: ... by your SNMP tool You can then use it Private MIB can be found in product CD or downloaded from Korenix Web site Private MIB tree is the same as the web tree This is easier to understand and use If you are not familiar with standard MIB you can directly use private MIB to manage monitor the switch no need to learn or find where the OIDs of the commands are The path of the JetNet 5008G P is 1 3 4 ...

Page 95: ...92 5 4 Revision History Edition Date Modifications V 1 0 Sep 11 2007 The first version ...

Page 96: ...l sales strategy focuses on establishing and developing trustworthy relationships with value added distributors and channel partners and assisting OEM distributors to promote their own brands Korenix supplies products to match local market requirements of design quality sales marketing and customer services allowing Korenix and distributors to create and enjoy profits together Quality Services Kor...

Reviews: