24
Example:
1. WTS305
2. WTS506
07
92(Wind Speed)
UINT16, Unit: m/s, Resolution: 0.1m/s
08
77(Rainfall)
3 Bytes
Byte 0-1: Accumulated rainfall, Unit: mm,
Resolution: 0.01 mm
B2: Frame counter to define whether device enters
the new rainfall accumulation phase, it will plus 1
every upload, range: 0~255
Note:
1) When the rainfall is cleared and start a new
accumulation phase, the counter will be also
cleared to 0;
2) When frame counter reaches 255 and not enter
a new phase, it will always upload 255.
017564 03671001 046871 05840001 0673aa27 07929201
Channel
Type
Value
Channel
Type
Value
01
75
(Battery)
64 =>
100%
03
67
(Temperature
)
10 01 => 01 10 = 272
Temp=272*0.1=27.2
°C
Channel
Type
Value
Channel
Type
Value
04
68
(Humidity)
71=>113
Hum=113*
0.5=56.5%
05
84
(Wind
Direction)
00 01=> 01 00 =
256°
Channel
Type
Value
Channel
Type
Value
06
73
(Barometric
Pressure)
aa 27=>27
aa=10154*
0.1=1015.
4 hPa
07
92(Wind
Speed)
92 01 => 01 92 =
402*0.1= 40.2 m/s
017564 03671001 046871 05844605 0673aa27 07929201 0877c41325
Channel
Type
Value
Channel
Type
Value
01
75
(Battery)
64 => 100%
03
67
(Temperatu
re)
10 01 => 01 10 =
272
Temp=272*0.1=2
7.2°C
Channel
Type
Value
Channel
Type
Value