8
①
Special data area (4 stations, 2 stations)
When the set value is registered by using the set value writing request (request 1), the set value is
set in each area.
Details of each set value are shown as follows;
Data type
Setting range
Final
32 bit binary with sign
0
~
999999
Brand number (8bit)
8 bit binary with sign
0
~
99
Preliminary 2
32 bit binary with sign
0
~
999999
Preliminary 1
16 bit binary with sign
0
~
32767
Free Fall
16 bit binary with sign
-32768
~
32767
Over
16 bit binary with sign
0
~
32767
Under
16 bit binary with sign
0
~
32767
Full
32 bit binary with sign
0
~
999999
Near zero
32 bit binary with sign
0
~
999999
②
General data area (4 stations, 2 stations)
When the command order is executed by using the general command request (request 2), the set
value or the operating order code is set in this area.
Data type
: 32 bit binary with sign
Setting range
: Depends on the set value.
③
Command No. (4 stations, 2 stations)
When the command order is executed by using the general command request (request 2), the
command No. is set in this area.
The content of the general data area is set depending on the command set in this area.
Data type
: 8 bit binary
Setting range
: 0
~
255
④
Operation mode (4 stations, 2 stations)
When the operation mode is changed by using the operation mode changeover request (request 3),
the mode number is set in this area.
This function is prepared for future expansion.
Data type
: 8 bit binary
Setting range
: 0
~
255
2)
Command
list
The command No. and the value which is set in General data area when the command order is
executed by using the general command request (request 2) are shown in the next page.