36
SOUR:VOLT2:PROTECTION:TRIG OFF ==> disable OVP for channel 2.
VOLTAGE3:PROT:TRIG ON
==> enable OVP for channel 3.
VOLT2:PROT:TRIGGER ON
==> enable OVP for channel 2.
VOLT1:PROTECTION:TRIG OFF
==> disable OVP for channel 1.
VOLT:PROTECTION:TRIG OFF
==> disable OVP for channel 1.
OVP2 ON
==> enable OVP for channel 2.
OVP3 OFF
==> disable OVP for channel 3.
Q62. How to enable or disable over current protection (OCP)?
SOUR:CURRENT3:PROT:TRIG ON
==> enable OCP for channel 3.
SOURCE:CURR1:PROT:TRIG OFF
==> disable OCP for channel 1.
SOUR:CURR2:PROTECTION:TRIG OFF ==> disable OCP for channel 2.
CURRENT3:PROT:TRIG ON
==> enable OCP for channel 3.
CURR2:PROT:TRIGGER ON
==> enable OCP for channel 2.
CURR1:PROTECTION:TRIG OFF
==> disable OCP for channel 1.
CURR:PROTECTION:TRIG OFF
==> disable OCP for channel 1.
OCP2 ON
==> enable OCP for channel 2.
OCP3 OFF
==> disable OCP for channel 3.
Q63. How to set up a program (example)?
PROG 10
==> define program 10
PROG:ISET1 1
==> set max. output current of 1A for ch1
PROG:ISET2 1
==> set max. output current of 1A for ch2
PROG:ISET3 1
==> set max. output current of 1A for ch3
PROG:VSET1 1
==> set output voltage of 1V for ch1
PROG:VSET2 1
==> set output voltage of 1V for ch2
PROG:VSET3 1
==> set output voltage of 1V for ch3
PROG:FAST 4
==> output above setting for 4 ms
PROG:NEXT:NEXT
==> go on to program 11
PROG?
==> read back the setting of program 10 for
verification
PROG 11
==> define program 11
PROG:ISET1 1
==> ch1 output up to 1 A
PROG:ISET2 1
==> ch2 output up to 1 A
PROG:ISET3 1
==> ch3 output up to 1 A
PROG:VSET1 3
==> ch1 output 3V
PROG:VSET2 3
==> ch2 output 3V
PROG:VSET3 3
==> ch3 output 3V
PROG:FAST 100
==> output above seeting for 100 ms
PROG:NEXT:JUMP 13
==> jump to program 13
PROG 12
==> define program 12
Summary of Contents for LPS 505N
Page 1: ...LPS 505N Programmable DC Power Supply User s Manual...
Page 2: ......
Page 6: ......
Page 8: ......
Page 49: ...ZOMG 505ME 1B...