Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
PDO mapping
no
Allowed values
Preset value
00000001
h
Subindex
0B
h
Name
Save Modbus RTU Configurations To Non-volatile Memory
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000001
h
Subindex
0C
h
Name
Save Ethernet Configurations To Non-volatile Memory
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000001
h
Subindex
0D
h
Name
Save Profibus Configurations To Non-volatile Memory
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000001
h
Description
Each subindex of the object stands for a certain memory class. By reading out the entry, it is possible
to determine whether (value "1") or not (value="0") this memory category can be saved.
To start the save process of a memory category, value "65766173
h
" must be written in the
corresponding subindex. This corresponds to the decimal of 1702257011
d
or the ASCII string
save
. As
soon as the saving process is completed, the save command is again overwritten with the value "1",
since saving is possible again.
For a detailed description, see chapter Saving objects.
1011h Restore Default Parameters
Function
This object can be used to reset all or part of the object dictionary to the default values. See chapter
Saving objects.
Version: 1.0.1 / FIR-v1748