EX Series Operating Manual
VOLT:STEP?
This query returns the value of the step size currently specified. The returned parameter is a
numeric value.
Return value "numeric value"
ex) volt:step?
return value "0.500"
VOLT:OVP {<numeric value>}
VOLT:OVP {<numeric value>}
This command sets the voltage level at which the overvoltage protection circuit will trip.
> numeric value
Input voltage within OVP setting range.
ex) volt:ovp 32
Set the OVP Level to 32V.
VOLT:OVP?
This query returns the overvoltage protection trip level presently programmed.
Return value "numeric value"
Return value "numeric value"
ex) volt:ovp?
return value "32.00"
VOLT:OVP:TRIP?
This query returns a ‘‘1’’ if the overvoltage protection circuit is tripped and not cleared or
a ‘‘0’’ if not tripped.
Return value "0" - not tripped state.
"1" - OVP Trip state and cut the output.
ex) volt:ovp:trip?
return value "1"
VOLT:OVP:CLE
This command causes the overvoltage protection circuit to be cleared
Before release trip, refer to "3-4. Programming Over Voltage Protection(OVP)" in other to check
the reason of trip occuring and remove this reason.
the reason of trip occuring and remove this reason.
ex) volt:ovp:cle
Clear the OVP Trip.
When appears OVP Trip, cut the voltage/current output. At that time, if you set the
voltage/current, it can be set. But DC output is still cut unless release the trip mode.
Note
- 87 -