Personal Daq User’s Manual
Appendix B,
887095
API Commands B-27
daqSetOption
DLL Function
daqSetOption(DaqHandleT handle, DWORD chan, DWORD flags, daqOptionType optionType,
FLOAT optionValue);
C
daqSetOption(DaqHandleT handle, DWORD chan, DWORD flags, DaqOptionType optionType,
FLOAT optionValue);
Visual BASIC
VBdaqSetOption&(ByVal handle&, ByVal chan&, ByVal flags&, ByVal optionType&, ByVal
optionValue!)
Delphi
daqSetOption(Handle:DaqHandleT; chan:DWORD; flags:DWORD; optionType:daqOptionType;
optionValue:FLOAT)
handle
The handle to the device for which to set the option
chan
The channel number on the device for which the option is to be set
flags
Flags specifying the options to use.
optionType
Specifies the type of option.
Parameters
optionValue
The value of the option to set
Returns
DerrNoError
No error
See Also
daqAdcExpSetChanOption,
Program References
PULSEEX1.C, MULTEX1.C, FREQEX1.C, DAQEX.FRM (VB), DAQEX.PAS (Delphi)
Used With
All devices
Description
daqSetOption
allows the setting of options for a device’s channel/signal path configuration.
chan
specifies which channel the option applies to.
flags
parameter specifies how the option is to be applied.
optionType
specifies the type of option to apply to the channel.
optionValue
parameter specifies the value of the option.
Note:
For more information regarding
optionValue
and
optionType
refer to page B-32, Table 8.
Note
: The following information does not apply to Personal Daq/54.
daqSetOption
must be used to properly configure Personal Daq’s frequency input and pulse count channels. To configure frequency input
and pulse count channels, the following option types need to be specified for each frequency input/pulse count channel in the scan
sequence:
DcotpDaqPulses
: Configures the specified channel as a pulse count channel.
DcotpDaqRising
: Configures the rising flag for the pulse channel.
DcotpDaqDebounceTime
: Configures the debounce time for the frequency/pulse channel.
The following options must also be specified to configure frequency input channels:
DcotpDaqMinFreq
: Configures the minimum frequency range for the specified channel.
DcotpDaqMaxFreq
: Configures the maximum frequency range for the specified channel.
DcotpDaqFreqRes
: Configures the resolution of the specified frequency channel.
DcotpDaqOverrangeProtect:
Enables the overrange protection mode.
daqSetTimeout
DLL Function
daqSetTimeout(DaqHandleT handle, DWORD mSecTimeout);
C
daqSetTimeout(DaqHandleT handle, DWORD mSecTimeout);
Visual BASIC
VBdaqSetTimeout&(ByVal handle&, ByVal mSecTimeout&)
Delphi
daqSetTimeout(handle:DaqHandleT; mSecTimeout:DWORD)
handle
Handle to the device for which the event time-out is to be set
Parameters
mSecTimeout
Specifies time-out ( ms ) for events
Returns
DerrNoError
No error
See Also
daqWaitForEvent, daqWaitForEvents
Program References
None
Used With
All devices
Description
daqSetTimeout
allows you to set the time-out for waiting on a single event or multiple events. This function can be used in conjunction
with the
daqWaitForEvent
and
daqWaitForEvents
functions to specify a maximum amount of time to wait for the event(s) to be
satisfied.
The
mSecTimeout
parameter specifies the maximum amount of time (in milliseconds) to wait for the event(s) to occur. If the event(s) do
not occur within the specified time-out, the
daqWaitForEvent
and/or
daqWaitForEvents
will return.