KS-6215 / KS-6215I / KS-6217 series Technical Manual 5 - 4
disconnected during the power off stage, such change will be discarded. Therefore, it is
advisable for the application program to reinstate the switch function every time the
system is rebooted or every time the program is executed to ensure the proper action
of the power switch. This function can also be achieved by use of the Posiflex Power
Switch Terminal Manager.
SOFTWARE SWITCH OFF
An easy method for software control to turn the system off is the software off
switch. The hexadecimal command string for software switch off function is :
<06> <16> <19> <1D> <n>.
In the above, the “n” indicates the time delay in seconds for actual power off
after the command string given to COM1. However, an alternative command string
<1B> <00> <00> <00> <00> <00> <00> <00> can be used instead to turn off the
system power immediately.
Some operating system or software may require complete termination of
application programs before system power off for the sake of system maintenance. In
that case the programmer has to program the command to close the application
programs (just like “Alt+F4” in Windows), and then at the end of the closing operation,
the application program should issue the above mentioned software switch off
command string to COM1 under the protocol: 9600 bps, parity none, 8 data bits, 1
stop bit.
FORCED POWER OFF
In case of serious system halt due to system resources conflict or any reason,
the system could fail to power off through normal means. The Forced Power Off
method is designed for such occasions. With the external power switch defined as
power ON/OFF switch (default status), push down and hold this Power ON/OFF
Switch. The system will be powered off within 10 seconds in this way. Whenever the
machine receives a software command to change the external power switch to ON only,
the forced power off function is disabled. However, an enhance power off command is
provided for the software programmer to allow forced power off after changing the
switch to be ON only. The enhance forced power off command string is <1B> <00>
<00> <00> <00> <00> <18> <18> and it has to be sent in same way like the ON only
Summary of Contents for Jiva KS-6215 Series