10.4.2
Call Parameters
Structure of the (parameter)
data field
Before calling OB 200, you must supply the input parameters in the
data field. OB 200 requires eight F flag bytes in the data field for input
and output parameters:
FY x + 0:
Mode (automatic/
manual )
input parameter
FY x + 1:
Number of CPUs
input parameter
FY x + 2:
Block ID
input parameter
FY x + 3:
Block number
input parameter
FY x + 4:
Start address of the
input parameter
FY x + 5:
assignment list
FY x + 6:
Condition code byte
output parameter
FY x + 7:
Total capacity
output parameter
ACCU-1-L
When OB 200 is called, you transfer the flag byte number at which the
parameter data field begins to ACCU-1-L:
ACCU-1-LH:
0
ACCU-1-LL:
0 to 246
10.4.3
Input Parameters
Mode (automatic/manual)
Mode = 1:
automatic
Mode = 2:
manual
Mode = 0 or 3 to 255:
illegal, causes an
initialization conflict
Number of CPUs
This parameter is only relevant when you have selected the
"automatic" mode. With the "automatic" setting, the memory fields
are divided evenly according to the number of CPUs.
Number of
CPUs
Number of
links
Memory fields per
link
2
3
4
2
6
12
24
8
4
0; 1; 5 to 255
Illegal, causes an initialization conflict
INITIALIZE Function (OB 200)
CPU 948 Programming Guide
C79000-G8576-C848-04
10 - 35
Summary of Contents for CPU 948
Page 10: ...Contents CPU 948 Programming Guide 1 2 C79000 G8576 C848 04 ...
Page 32: ...Contents CPU 948 Programming Guide 2 2 C79000 G8576 C848 04 ...
Page 72: ...Data Blocks CPU 948 Programming Guide 2 42 C79000 G8576 C848 04 ...
Page 74: ...Contents CPU 948 Programming Guide 3 2 C79000 G8576 C848 04 ...
Page 154: ...Contents CPU 948 Programming Guide 4 2 C79000 G8576 C848 04 ...
Page 200: ...Contents CPU 948 Programming Guide 5 2 C79000 G8576 C848 04 ...
Page 308: ...Contents CPU 948 Programming Guide 7 2 C79000 G8576 C848 04 ...
Page 324: ...Examples of Parameter Assignment CPU 948 Programming Guide 7 18 C79000 G8576 C848 04 ...
Page 326: ...Contents CPU 948 Programming Guide 8 2 C79000 G8576 C848 04 ...
Page 370: ...Addressable System Data Area CPU 948 Programming Guide 8 46 C79000 G8576 C848 04 ...
Page 372: ...Contents CPU 948 Programming Guide 9 2 C79000 G8576 C848 04 ...
Page 486: ...Contents CPU 948 Programming Guide 11 2 C79000 G8576 C848 04 ...
Page 522: ...PG Functions via the S5 Bus CPU 948 Programming Guide 11 38 C79000 G8576 C848 04 ...
Page 524: ...Contents CPU 948 Programming Guide 12 2 C79000 G8576 C848 04 ...
Page 538: ...Contents CPU 948 Programming Guide 13 2 C79000 G8576 C848 04 ...
Page 546: ...List of Key Words CPU 948 Programming Guide Index 6 C79000 G8576 C848 04 ...