Configuration / project engineering
5.7 Configuration with the Command Line Interface
SCALANCE W786-xPRO
182
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
Comment
Write and read access can also be
set for the group:
R Read
access
W Write
access
You cannot edit the authentication and encryption
settings unless the group is empty.
Preventing read access also prevents write access.
Permitting write access also permits read access.
Changes the security level of the
group and sets the access rights.
You can display the index of the
group with the "info
“
command.
RE
Enables read access
RD Disables
read
access
WE Enables
write
access
edit <Index>
[NOAUTH|AUTH|PRIV]
[RE|RD|WE|WD]
WD
Disables write access
ᅳ
✔
✔
✔
✔
✔
Is only possible to delete a group if it is empty.
delete <Index>
Deletes the SNMPv3 group from the
group list at the index position.
ᅳ
✔
✔
✔
✔
✔
clearall
Clears all SNMP groups that are
empty.
ᅳ
✔
✔
✔
✔
✔
See also
SNMP Config menu command (Page 103)
5.7.2.9
CLI
\
SYSTEM
\
SNMP
\
USER menu command
Managing SNMP users
With the commands in this menu, you manage SNMP users (creating, deleting etc.).
CLI
\
SYSTEM
\
SNMP
\
USER>
Comment
Command Description
IWLAN/
PB LINK
W744 W746 W747 W78x
W78x
RR
The authentication password and the encryption
password can be a maximum of 63 characters long.
add <user name> <group
name> [NONE|MD5|SHA]
[authentication pw]
[encryption pw]
Assigns an SNMPv3 user
to a group.
If authentication is
necessary for the group,
the algorithm must be
specified as a parameter
(MD5 or SHA).
If encryption is necessary
for the group, the
encryption password must
be specified as a
parameter.
ᅳ
✔
✔
✔
✔
✔